文献速递乳腺乳腺X线

乳腺癌风险与数字乳腺X线摄影密度在像素亮度阈值和乳腺摄影系统上的关联

Breast Cancer Risk Associations with Digital Mammographic Density by Pixel Brightness Threshold and Mammographic System.
PubMed 文献 · Radiology · 2017-10-16

韩国乳腺癌研究纳入398例浸润性乳腺癌患者和737名年龄、检查日期、乳腺摄影系统及绝经状态匹配的对照,用LIBRA和Cumulus在常规及递增像素亮度阈值下测量乳腺密度并评估风险预测。直接转换系统下Cirrocumulus的OPERA为3.48、AUC为0.89;间接转换系统下各阈值OPERA为1.36–1.50、AUC为0.60–0.64。

要点

  • 直接转换系统下,Cirrocumulus阈值测量的致密面积风险预测能力最高(OPERA 3.48,AUC 0.89)。
  • 间接转换系统下,各阈值密度测量的OPERA为1.36–1.50、AUC为0.60–0.64,预测能力较低。
  • 乳腺摄影上高亮度而非单纯白色区域可能在病因学上更重要。

核心结论

  • 使用直接转换乳腺摄影系统时,更高像素阈值定义的乳腺密度可能捕获更多风险预测信息;乳腺摄影上高亮度而非白色区域在病因学上重要。

研究设计与样本

  • 韩国乳腺癌研究,纳入398例浸润性乳腺癌患者和737名对照,按乳腺摄影时年龄(±1岁)、检查日期、乳腺摄影系统和绝经状态匹配。
  • 乳腺密度用自动LIBRA软件和半自动Cumulus软件在常规阈值(Cumulus)及递增更高阈值(Altocumulus和Cirrocumulus)下测量。
  • 测量值经Box-Cox变换并校正年龄、体重指数和绝经状态,用条件logistic回归估计风险关联。

诊断标准与关键数值

  • 直接转换系统致密面积:LIBRA的OPERA为1.72(95%CI:1.38, 2.15),Cumulus为1.58(95%CI:1.27, 1.97),Altocumulus为2.04(95%CI:1.60, 2.59),Cirrocumulus为3.48(95%CI:2.45, 4.47)(P < .001)。
  • 直接转换系统致密面积对应AUC分别为0.70、0.69、0.76和0.89。
  • 间接转换系统致密面积:LIBRA的OPERA为1.50(95%CI:1.28, 1.76),Cumulus为1.36(95%CI:1.16, 1.59),Altocumulus为1.40(95%CI:1.19, 1.64),Cirrocumulus为1.47(95%CI:1.25, 1.73)(P < .001)。
  • 间接转换系统致密面积对应AUC分别为0.64、0.60、0.61和0.63。

临床应用与阅片要点

  • 使用直接转换乳腺摄影系统时,递增像素亮度阈值(Cirrocumulus)测量的致密面积风险预测能力最高。
  • 间接转换系统下各阈值密度测量的风险预测能力较低,原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare three mammographic density measures defined by different pixel intensity thresholds as predictors of breast cancer risk for two different digital mammographic systems. Materials and Methods The Korean Breast Cancer Study included 398 women with invasive breast cancer and 737 control participants matched for age at mammography (±1 year), examination date, mammographic system, and menopausal status. Mammographic density was measured by using the automated Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) software and the semiautomated Cumulus software at the conventional threshold (Cumulus) and at increasingly higher thresholds (Altocumulus and Cirrocumulus, respectively). Measures were Box-Cox-transformed and adjusted for age, body mass index, and menopausal status. Conditional logistic regression was used to estimate risk associations. For calculation of measures of predictive value, the change in odds per standard deviation (OPERA) and the area under the receiver operating characteristic curve (AUC) were used. Results For dense area, with use of the direct conversion system the OPERAs were 1.72 (95% confidence interval [CI]: 1.38, 2.15) for LIBRA, 1.58 (95% CI: 1.27, 1.97) for Cumulus, 2.04 (95% CI: 1.60, 2.59) for Altocumulus, and 3.48 (95% CI: 2.45, 4.47) for Cirrocumulus (P < .001). The corresponding AUCs were 0.70, 0.69, 0.76, and 0.89, respectively. With use of the indirect conversion system, the corresponding OPERAs were 1.50 (95% CI: 1.28, 1.76), 1.36 (95% CI: 1.16, 1.59), 1.40 (95% CI: 1.19, 1.64), and 1.47 (95% CI: 1.25, 1.73) (P < .001) and the AUCs were 0.64, 0.60, 0.61, and 0.63, respectively. Conclusion It is possible that mammographic density defined by higher pixel thresholds could capture more risk-predicting information with use of a direct conversion mammographic system; the mammographically bright, rather than white, regions are etiologically important. © RSNA, 2017.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Nguyen TL, Choi YH, Aung YK, et al. Breast Cancer Risk Associations with Digital Mammographic Density by Pixel Brightness Threshold and Mammographic System. Radiology. 2017. PMID: 29040039. doi:10.1148/radiol.2017170306