文献速递乳腺乳腺X线

多阅片者多病例研究中并行计算机辅助检测可缩短数字乳腺断层摄影阅片时间并维持判读性能

Concurrent Computer-Aided Detection Improves Reading Time of Digital Breast Tomosynthesis and Maintains Interpretation Performance in a Multireader Multicase Study.
PubMed 文献 · AJR Am J Roentgenol · 2017-10-24

本研究为多阅片者多病例交叉设计,纳入240例数字乳腺断层摄影(DBT)病例(61例患者中68个恶性肿瘤),20名放射科医生在有/无并行计算机辅助检测(CAD)条件下回顾性判读,比较阅片时间与判读性能。结果显示CAD使阅片时间缩短29.2%(95%CI 21.1-36.5%,P<0.01),以ROC AUC衡量的判读性能非劣效(P<0.01),平均AUC从无CAD的0.841升至有CAD的0.850(95%CI -0.012至0.030)。结论认为并行使用CAD使DBT阅片时间加快29.2%并维持判读性能。

要点

  • 并行CAD使DBT阅片时间缩短29.2%(95%CI 21.1-36.5%,P<0.01)。
  • 有CAD时平均AUC 0.850 vs 无CAD 0.841(95%CI -0.012至0.030),判读性能非劣效(P<0.01)。
  • 有CAD时平均敏感度0.871 vs 无CAD 0.847(差值95%CI -0.005至0.055)。

核心结论

  • 并行使用CAD与DBT可使阅片时间加快29.2%,同时维持判读者判读性能。

研究设计与样本

  • 多阅片者多病例交叉设计,20名放射科医生回顾性判读240例DBT病例(61例患者中68个恶性肿瘤),比较有/无CAD的阅片时间与判读性能,并单独评估CAD性能。
  • CAD系统用于检测DBT层面中的可疑软组织密度,将异常从检出层面提取并融合至对应合成图像。

关键影像表现/征象

  • CAD系统检测DBT层面中的可疑软组织密度,并将异常从检出层面提取融合至对应合成图像。

诊断标准与关键数值

  • 有CAD时平均AUC 0.850 vs 无CAD 0.841(95%CI -0.012至0.030),判读性能非劣效(P<0.01)。
  • 有CAD时平均敏感度0.871 vs 无CAD 0.847(差值95%CI -0.005至0.055)。
  • 有CAD时软组织密度病例敏感度增加0.033(95%CI -0.002至0.068)。
  • 有CAD时平均特异度0.509 vs 无CAD 0.527(差值95%CI -0.041至0.005)。
  • 有CAD时非癌病例平均召回率0.492 vs 无CAD 0.474(差值95%CI -0.006至0.041)。

临床应用与阅片要点

  • 原文结论为并行使用CAD与DBT可使阅片时间加快29.2%并维持判读性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Digital breast tomosynthesis (DBT) is more accurate than full-field digital mammography alone but requires a longer reading time. A radiologist reader study evaluated the use of concurrent computer-aided detection (CAD) to shorten the reading time while maintaining interpretation performance.

MATERIALS AND METHODS: A CAD system was developed to detect suspicious soft-tissue densities in DBT planes. Abnormalities are extracted from the plane in which they are detected and blended into the corresponding synthetic image. The study used an enriched sample of 240 DBT cases with 68 malignancies in 61 patients. Twenty radiologists retrospectively reviewed all 240 cases in a multireader multicase crossover design to compare reading time and performance with and without CAD. The performance of CAD alone was also evaluated.

RESULTS: Reading time improved by 29.2% with CAD (95% CI, 21.1-36.5%; p < 0.01). Reader performance, measured by ROC AUC, was noninferior with CAD (p < 0.01). The mean AUC increased from 0.841 without to 0.850 with CAD (95% CI, -0.012 to 0.030). Mean sensitivity increased from 0.847 without to 0.871 with CAD (difference 95% CI, -0.005 to 0.055), showing a 0.033 increase in sensitivity for cases with soft-tissue densities (95% CI, -0.002 to 0.068). Mean specificity decreased from 0.527 without to 0.509 with CAD (difference 95% CI, -0.041 to 0.005), and mean recall rate for noncancers slightly increased from 0.474 without to 0.492 with CAD (difference 95% CI, -0.006 to 0.041).

CONCLUSION: Concurrent use of CAD with DBT resulted in 29.2% faster reading time, while maintaining reader interpretation performance.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Benedikt RA, Boatsman JE, Swann CA, et al. Concurrent Computer-Aided Detection Improves Reading Time of Digital Breast Tomosynthesis and Maintains Interpretation Performance in a Multireader Multicase Study. AJR Am J Roentgenol. 2017. PMID: 29064756. doi:10.2214/AJR.17.18185

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。