乳腺X线摄影新发不对称的超声特征及其与组织病理学表现的相关性
回顾性分析2009至2012年间201例乳腺X线摄影新发不对称患者,其中78例有超声对应发现,46.2%为肿块,53.8%为非肿块表现;26.9%为恶性,恶性者81.0%表现为低回声肿块,19.0%表现为非肿块。
要点
- 新发不对称的超声对应发现中,非肿块表现占53.8%,且多为混合回声。
- 恶性新发不对称伴超声对应发现者,81.0%表现为低回声肿块。
- 恶性者中19.0%表现为非肿块,回声为混合或低回声。
核心结论
- 新发不对称的超声对应发现常为非肿块表现且呈混合回声;恶性者多表现为低回声肿块,但19%表现为非肿块。
研究设计与样本
- 回顾性研究,检索2009至2012年一家学术医学中心、附属癌症中心及两家门诊影像机构的乳腺X线摄影数据库,201例新发不对称患者中187例有诊断时或1个月内超声,最终78例有超声对应发现者纳入研究;超声特征由共识阅片获得,结局来自电子病历。
关键影像表现/征象
- 78例超声对应发现中36例(46.2%)为肿块:26例(72.2%)低回声,4例(11.1%)高回声,3例(8.3%)混合高回声与低回声,3例(8.3%)无回声。
- 78例中42例(53.8%)为非肿块表现:24例(57.1%)混合高回声与低回声,13例(31.0%)低回声,5例(11.9%)高回声。
- 78例中21例(26.9%)为恶性:8例浸润性导管癌,7例浸润性小叶癌,3例混合浸润性导管和小叶癌,3例导管原位癌。
- 恶性病变超声表现:17例(81.0%)为肿块(13例低回声,4例混合高回声与低回声),4例(19.0%)为非肿块(3例混合高回声与低回声,1例低回声)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study is to review the ultrasound (US) features of developing asymmetries and correlate them with histopathologic findings.
MATERIALS AND METHODS: We searched the mammography database of an academic medical center, affiliated cancer center, and two ambulatory imaging facilities from 2009 to 2012 and identified 201 patients with developing asymmetries, 187 of whom had US at the time of, or within 1 month of, diagnostic mammography evaluation. Seventy-five (40.1%) of these 187 patients had a US correlate, and three additional patients had a positive second-look US after MRI (US results were initially negative), and one patient had a US correlate for a newly palpable developing asymmetry 1 month after receiving a BI-RADS category 3 mammography-only assessment. These 78 developing asymmetries with US correlates comprised the study cases. US features were obtained by consensus image review; patient demographic characteristics and outcomes were obtained from the electronic medical record.
RESULTS: Thirty-six of 78 US correlates (46.2%) were masses, the echotexture of which was as follows: 26 (72.2%) were hypoechoic, four (11.1%) were hyperechoic, three (8.3%) were mixed hyperechoic and hypoechoic, and three (8.3%) were anechoic. Forty-two of 78 US correlates (53.8%) were nonmass findings, the echotexture of which was as follows: 24 (57.1%) were mixed hyperechoic and hypoechoic, 13 (31.0%) were hypoechoic, and five (11.9%) were hyperechoic. Twenty-one of 78 lesions (26.9%) were malignant; of these, eight were invasive ductal carcinoma, seven were invasive lobular carcinoma, three were mixed invasive ductal and lobular carcinoma, and three were ductal carcinoma in situ. Malignant findings on US included 17 masses (81.0%) (13 hypoechoic and four mixed hyperechoic and hypoechoic), and four nonmass findings (19.0%) (three mixed hyperechoic and hypoechoic and one hypoechoic).
CONCLUSION: When present, US correlates for developing asymmetries are often nonmass findings with mixed echotexture. Most malignant developing asymmetries with US correlates present as a hypoechoic mass, but 19% present as a nonmass finding with either mixed hyperechoic and hypoechoic echotexture or hypoechoic echotexture.
引用
- Giess CS, Chesebro AL, Chikarmane SA, et al. Ultrasound Features of Mammographic Developing Asymmetries and Correlation With Histopathologic Findings. AJR Am J Roentgenol. 2017. PMID: 29064753. doi:10.2214/AJR.17.18223
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。