文献速递妇产影像US

三维经会阴超声上耻骨直肠肌的自动分割

Automatic segmentation of puborectalis muscle on three-dimensional transperineal ultrasound.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-01-01

本研究基于12周妊娠初产妇的三维经会阴超声序列,提出耻骨直肠肌手动三维分割协议并用50名女性手动分割数据训练主动外观模型实现自动分割;手动分割组内与组间信度很好,手动与自动分割的平均回声ICC为0.968、体积ICC为0.626,自动分割成功率为90%。

要点

  • 手动三维分割耻骨直肠肌的组间与组内信度很好,平均回声ICC分别为0.987和0.991。
  • 手动与自动分割比较:平均回声ICC 0.968(很好),体积ICC 0.626(好)。
  • 自动分割基于重叠与距离检测到5例不匹配,自动分割成功率为90%。

核心结论

  • 本研究提出可靠的耻骨直肠肌手动分割协议和自动三维分割方法,将促进未来对耻骨直肠肌的研究,使平均回声等潜在有临床价值参数得以可靠测量。

研究设计与样本

  • 基于12周妊娠单胎初产妇三维经会阴超声序列开发耻骨直肠肌手动三维分割协议;自动分割采用主动外观模型,以50名女性的手动分割数据训练;手动方法信度评估使用20名女性数据,通过分割间重叠与距离分析性能。

诊断标准与关键数值

  • 手动分割组间信度:平均回声ICC 0.987,体积ICC 0.910。
  • 手动分割组内信度:平均回声ICC 0.991,体积ICC 0.877。
  • 手动与自动分割比较:平均回声ICC 0.968(很好),体积ICC 0.626(好)。
  • 手动分割平均不匹配仅2–3像素,重叠合理;自动分割检测到5例不匹配,自动分割成功率为90%。

临床应用与阅片要点

  • 手动三维分割协议可用于耻骨直肠肌的平均回声与体积测量,组内与组间信度很好。
  • 自动分割对平均回声与手动分割一致性很好(ICC 0.968),对体积一致性为好(ICC 0.626)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The introduction of three-dimensional (3D) analysis of the puborectalis muscle (PRM) for diagnostic purposes into daily practice is hindered by the need for appropriate training of observers. Automatic segmentation of the PRM on 3D transperineal ultrasound may aid its integration into clinical practice. The aims of this study were to present and assess a protocol for manual 3D segmentation of the PRM on 3D transperineal ultrasound, and to use this for training of automatic 3D segmentation method of the PRM.

METHODS: The data used in this study were derived from 3D transperineal ultrasound sequences of the pelvic floor acquired at 12 weeks' gestation from nulliparous women with a singleton pregnancy. A manual 3D segmentation protocol was developed for the PRM based on a validated two-dimensional segmentation protocol. For automatic segmentation, active appearance models of the PRM were developed, trained using manual segmentation data from 50 women. The performances of both manual and automatic segmentation were analyzed by measuring the overlap and distance between the segmentations. Intraclass correlation coefficients (ICCs) and their 95% CIs were determined for mean echogenicity and volume of the puborectalis muscle, in order to assess inter- and intraobserver reliabilities of the manual method using data from 20 women, as well as to compare the manual and automatic methods.

RESULTS: Interobserver reliabilities for mean echogenicity and volume were very good for manual segmentation (ICCs 0.987 and 0.910, respectively), as were intraobserver reliabilities (ICCs 0.991 and 0.877, respectively). ICCs for mean echogenicity and volume were very good and good, respectively, for the comparison of manual vs automatic segmentation (0.968 and 0.626, respectively). The overlap and distance results for manual segmentation were as expected, showing an average mismatch of only 2-3 pixels and reasonable overlap. Based on overlap and distance, five mismatches were detected for automatic segmentation, resulting in an automatic segmentation success rate of 90%.

CONCLUSIONS: This study presents a reliable manual segmentation protocol and automatic 3D segmentation method for the PRM, which will facilitate future investigation of the PRM, allowing for the reliable measurement of potentially clinically valuable parameters such as mean echogenicity. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology Published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. van den Noort F, Grob ATM, Slump CH, et al. Automatic segmentation of puborectalis muscle on three-dimensional transperineal ultrasound. Ultrasound Obstet Gynecol. 2018. PMID: 29024119. doi:10.1002/uog.18927

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。