CT尿路造影与肾动态显像Gates法测定单肾肾小球滤过率的对比
前瞻性纳入36例肾积水患者,比较基于CT尿路造影图像计算的单肾CT-GFR与99mTc-DTPA肾动态显像Gates-GFR。单肾CT-GFR为45.02±13.91 ml/min,Gates-GFR为51.21±14.76 ml/min,配对差值6.19±5.63 ml/min(p<0.001),CT法系统性低估12.1%,测量偏差±11.03 ml/min(±21.5%),两者相关性良好(r=0.87,p<0.001)。作者认为该CT-GFR与参考标准相关性和一致性良好,尽管存在系统性低估,可作为一站式评估尿路形态和分肾功能的方法。
要点
- 单肾CT-GFR较Gates-GFR系统性低估12.1%,配对差值6.19±5.63 ml/min(p<0.001)。
- 两者相关性良好(r=0.87,p<0.001),测量偏差±11.03 ml/min(±21.5%)。
- CT-GFR仅需CT尿路造影图像和血细胞比容值,不增加额外辐射剂量。
核心结论
- 所提出的单肾CT-GFR与参考标准相关性及一致性良好,尽管存在系统性低估,可能成为一站式评估尿路形态和分肾功能的方法。
研究设计与样本
- 前瞻性纳入36例因肾积水转诊行CT尿路造影和99mTc-DTPA肾动态显像的患者,所有患者均签署知情同意书。
- CT尿路造影方案包括平扫期、肾实质期和排泄期成像。
- 总CT-GFR计算方法:将肾实质期与排泄期之间整个泌尿系统CT值增量除以主动脉碘浓度与经过时间的乘积,再乘以(1-血细胞比容)。
- 总CT-GFR按左右肾比例因子拆分为单肾CT-GFR,并与单肾Gates-GFR采用配对t检验、相关分析和Bland-Altman图比较。
诊断标准与关键数值
- 单肾CT-GFR为45.02±13.91 ml/min,单肾Gates-GFR为51.21±14.76 ml/min。
- 配对差值为6.19±5.63 ml/min(p<0.001),CT法系统性低估12.1%,测量偏差±11.03 ml/min(±21.5%)。
- 两种测量方法相关性良好(r=0.87,p<0.001)。
临床应用与阅片要点
- 作者认为单肾CT-GFR与参考标准相关性和一致性良好,尽管存在系统性低估,可能成为一站式评估尿路形态和分肾功能的方法。
- 该方法仅使用CT尿路造影图像和血细胞比容值,不增加额外辐射剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To present a single-kidney CT-GFR measurement and compare it with the renal dynamic imaging Gates-GFR.
MATERIALS AND METHODS: Thirty-six patients with hydronephrosis referred for CT urography and 99mTc-DTPA renal dynamic imaging were prospectively included. Informed consent was obtained from all patients. The CT urography protocol included non-contrast, nephrographic, and excretory phase imaging. The total CT-GFR was calculated by dividing the CT number increments of the total urinary system between the nephrographic and excretory phase by the products of iodine concentration in the aorta and the elapsed time, then multiplied by (1- Haematocrit). The total CT-GFR was then split into single-kidney CT-GFR by a left and right kidney proportionality factor. The results were compared with single-kidney Gates-GFR by using paired t-test, correlation analysis, and Bland-Altman plots.
RESULTS: Paired difference between single-kidney CT-GFR (45.02 ± 13.91) and single-kidney Gates-GFR (51.21 ± 14.76) was 6.19 ± 5.63 ml/min, p<0.001, demonstrating 12.1% systematic underestimation with ±11.03 ml/min (±21.5%) measurement deviation. A good correlation was revealed between both measurements (r=0.87, p<0.001).
CONCLUSION: The proposed single-kidney CT-GFR correlates and agrees well with the reference standard despite a systematic underestimation, therefore it could be a one-stop-shop for evaluating urinary tract morphology and split renal function.
KEY POINTS: • A new CT method can assess split renal function • Only using images from CT urography and the value of haematocrit • A one-stop-shop CT technique without additional radiation dose.
引用
- You S, Ma X, Zhang C, et al. Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method. Eur Radiol. 2017. PMID: 28971295. doi:10.1007/s00330-017-5061-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。