文献速递泌尿生殖腹部MR

MRI预测膀胱癌肌层浸润性的诊断效能:系统评价与Meta分析

Diagnostic performance of MRI for prediction of muscle-invasiveness of bladder cancer: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2017-07-29

该系统评价与Meta分析纳入24项研究共1774例患者,评估≥1.5-T MRI对膀胱癌局部分期(≥T2即肌层浸润)的诊断准确性,以病理为参考标准。汇总敏感度为0.92(95%CI 0.88-0.95),特异度为0.87(95%CI 0.78-0.93);3-T扫描仪特异度高于1.5-T,多参数MRI(常规+≥2个功能序列)敏感度和特异度分别为0.94(95%CI 0.89-1.00)和0.95(95%CI 0.89-0.98)。

要点

  • MRI预测膀胱癌肌层浸润的汇总敏感度0.92、特异度0.87。
  • 3-T扫描仪特异度0.93高于1.5-T的0.83,敏感度各亚组均高且相近。
  • 多参数MRI(常规+≥2个功能序列)敏感度0.94、特异度0.95,准确性最高。

核心结论

  • MRI对预测膀胱癌肌层浸润性显示出良好的诊断效能;多参数3-T MRI似乎可同时提高敏感度和特异度。

研究设计与样本

  • 系统评价与Meta分析,检索MEDLINE和EMBASE至2017年2月21日,纳入2000年以来发表的、使用≥1.5-T MRI对膀胱癌进行局部分期(≥T2即肌层浸润)并以病理为参考标准的诊断准确性研究,共24项研究1774例患者;采用诊断准确性研究质量评价工具第2版(QUADAS-2)评估方法学质量。

诊断标准与关键数值

  • 以病理为参考标准,MRI预测肌层浸润(≥T2)的汇总敏感度0.92(95%CI 0.88-0.95)、特异度0.87(95%CI 0.78-0.93)。

临床应用与阅片要点

  • 原文结论为MRI对预测膀胱癌肌层浸润性具有良好的诊断效能;作者认为多参数3-T MRI似乎可同时提高敏感度和特异度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To review the diagnostic performance of ≥1.5-T MRI for local staging of bladder cancer.

METHODS: MEDLINE and EMBASE were searched up to February 21, 2017. We included diagnostic accuracy studies published since 2000 that used ≥1.5-T MRI for local staging (≥T2 [muscle-invasive]) in patients with bladder cancer, using pathology as the reference standard. The methodological quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2. Sensitivity and specificity were pooled and plotted in a hierarchical summary receiver operating characteristics plot. Sensitivity analyses using several clinically relevant covariates were performed.

RESULTS: 24 studies (1774 patients) were included. Pooled sensitivity was 0.92 (95% CI 0.88-0.95) with specificity of 0.87 (95% CI 0.78-0.93). Sensitivity analyses showed that sensitivity estimates were comparable and consistently high across all subgroups, but specificity estimates were variable. Studies using 3-T scanners had higher specificity (0.93 [95% CI 0.86-0.98]) than those using 1.5-T scanners (0.83 [95% CI 0.74-0.98]). Studies using multiparametric MRI (conventional+≥2 functional sequences) showed the highest accuracy with sensitivity and specificity of 0.94 (95% CI 0.89-1.00) and 0.95 (95% CI 0.89-0.98), respectively.

CONCLUSIONS: MRI shows good diagnostic performance for predicting muscle-invasiveness of bladder cancer. Multiparametric 3-T MRI seems to improve both sensitivity and specificity.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Woo S, Suh CH, Kim SY, et al. Diagnostic performance of MRI for prediction of muscle-invasiveness of bladder cancer: A systematic review and meta-analysis. Eur J Radiol. 2017. PMID: 28987698. doi:10.1016/j.ejrad.2017.07.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。