睾丸磁共振扩散张量成像:初步观察
研究纳入56例男性行阴囊MRI含扩散张量成像(DTI),比较正常睾丸上、中、下三分之一及双侧间的ADC与FA值,并比较正常睾丸、恶性与良性病变的ADC和FA;结果显示正常睾丸各区及双侧间ADC与FA无显著差异,恶性肿瘤ADC显著低于正常睾丸和良性病变,良恶性病变FA均高于正常睾丸但两者间无差异,提示FA较ADC无增量鉴别价值。
要点
- 正常睾丸上、中、下三分之一及双侧对应区间的ADC与FA值无显著差异。
- 恶性肿瘤ADC显著低于正常睾丸(P=0.006)和良性病变(P=0.006)。
- 良恶性病变FA均高于正常睾丸,但恶性与良性病变间FA无显著差异(P=0.221)。
核心结论
- 睾丸DTI可行;ADC和FA在睾丸病变与正常睾丸间存在显著差异,但FA在病变鉴别方面较ADC无增量诊断价值。
研究设计与样本
- 前瞻性可行性研究,纳入56例男性行阴囊MRI(含DTI),采用参数和非参数统计检验比较正常睾丸不同区域及双侧间的ADC和FA,并比较正常睾丸、恶性与良性睾丸病变的ADC和FA。
关键影像表现/征象
- 正常睾丸上、中、下三分之一及双侧对应区间的ADC和FA无显著差异。
- 恶性肿瘤ADC较正常睾丸显著降低(P=0.006),较良性睾丸病变亦显著降低(P=0.006)。
- 恶性肿瘤FA较正常睾丸显著升高(P=0.001),良性病变FA较正常睾丸亦显著升高(P<0.001)。
- 恶性肿瘤与良性病变之间FA无显著差异(P=0.221)。
诊断标准与关键数值
- 恶性肿瘤ADC显著低于正常睾丸(P=0.006)。
- 恶性肿瘤ADC显著低于良性睾丸病变(P=0.006)。
- 恶性肿瘤FA显著高于正常睾丸(P=0.001)。
- 良性病变FA显著高于正常睾丸(P<0.001)。
- 恶性肿瘤FA与良性病变FA无显著差异(P=0.221)。
临床应用与阅片要点
- 睾丸DTI可评估ADC和FA,正常睾丸各区及双侧ADC和FA无显著差异。
- ADC有助于区分恶性肿瘤与正常睾丸及良性病变。
- FA在良恶性病变鉴别方面较ADC无增量诊断价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: To evaluate the feasibility of testis diffusion tensor imaging (DTI), to determine normative apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values and to assess the efficacy of DTI in characterizing testicular pathology.
MATERIALS AND METHODS: Fifty-six men underwent MRI of the scrotum, including DTI. Parametric and non-parametric statistical tests were used to compare the ADC and FA between the cranial, middle and lower thirds of normal testis and between the bilateral testicular thirds. Comparison between the ADC and FA of normal testis, malignant and benign testicular lesions was performed.
RESULTS: No significant differences of the ADC and FA in normal testis between the cranial, middle and lower thirds and between the bilateral testicular thirds were found. ADC was significantly lower in malignancies compared to normal testis (P=0.006) and benign testicular lesions (P=0.006). FA was significantly higher both in malignancies (P=0.001) and benign lesions (P<0.001) compared to normal testis. FA in malignancies did not differ from FA in benign lesions (P=0.221) CONCLUSIONS: This study shows the feasibility of testis DTI. Both ADC and FA significantly differ between testicular lesions and normal testis, although FA did not show an incremental diagnostic value compared to ADC in lesion differentiation.
引用
- Tsili AC, Ntorkou A, Astrakas L, et al. Magnetic resonance diffusion tensor imaging of the testis: Preliminary observations. Eur J Radiol. 2017. PMID: 28987678. doi:10.1016/j.ejrad.2017.08.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。