前列腺癌表观扩散系数值:2D与3D感兴趣区比较
研究纳入56例前列腺癌患者,根治性前列腺切除术前行3-T MRI(DWI b=50和1000 s/mm²),比较2D与3D ROI测量ADC的可重复性和诊断性能。3D ROI在可重复性和诊断性能上均未优于2D ROI,且2D ROI的组间可重复性仍欠佳。
要点
- 2D与3D ROI诊断良恶性病灶的AUC分别为0.77与0.78,无显著差异(p=0.146)。
- 区分GS 3+3与GS>3+3肿瘤的AUC均为0.92,无显著差异(p=0.649)。
- 3D ROI未改善可重复性或诊断性能,且组间可重复性欠佳。
核心结论
- 与2D ROI相比,3D ROI未改善前列腺ADC测量的组内或组间可重复性及诊断性能,但2D ROI的组间可重复性仍欠佳。
研究设计与样本
- 研究纳入56例前列腺癌患者,根治性前列腺切除术前接受3-T MRI(DWI b=50和1000 s/mm²),以前列腺切除标本组织学所见为参考标准,由3名阅片者独立测量。
诊断标准与关键数值
- 组内重复性系数:所有ROI为2D 9.9% vs 3D 9.3%;肿瘤ROI为2D 10.6% vs 3D 9.6%。
- 组间重复性系数:所有ROI为2D 17.1% vs 3D 20.5%;肿瘤ROI为2D 17.9% vs 3D 22.2%。
- 合并阅片者数据诊断良恶性的AUC:2D 0.77 vs 3D 0.78(p=0.146)。
- 区分GS 3+3与GS>3+3肿瘤的AUC:2D 0.92 vs 3D 0.92(p=0.649)。
- 区分GS≤3+4与GS≥4+3肿瘤的AUC:2D 0.70 vs 3D 0.67(p=0.004)。
临床应用与阅片要点
- 作者结论认为,与2D ROI相比,3D ROI未改善前列腺ADC测量的组内或组间可重复性及诊断性能。
- 作者指出,2D ROI的组间可重复性仍欠佳。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to compare the reproducibility and diagnostic performance of 2D and 3D ROIs for prostate apparent diffusion coefficient (ADC) measurements.
MATERIALS AND METHODS: The study included 56 patients with prostate cancer undergoing 3-T MRI including DWI (b = 50 and 1000 s/mm2) before radical prostatectomy. Histologic findings from prostatectomy specimens were reviewed to denote each patient's dominant tumor and a benign region with visually decreased ADC. Three readers independently measured the ADCs of both areas using an ROI placed on a single slice through the lesion (2D) and an ROI encompassing all slices through the lesion (3D). Readers repeated measurements after 3 weeks. Assessment included Bland-Altman analysis (coefficient of repeatability [CR] in which lower values indicated higher reliability) and ROC analysis.
RESULTS: For intrareader variability, the CRs across readers for all ROIs were 9.9% for 2D and 9.3% for 3D. For tumor ROIs the CRs were 10.6% for 2D and 9.6% for 3D. For interreader variability, the CRs across readers for all ROIs were 17.1% for 2D and 20.5% for 3D and for tumor ROIs were 17.9% for 2D and 22.2% for 3D. For combined reader data, the AUCs for benign and malignant findings were 0.77 for 2D and 0.78 for 3D (p = 0.146). For differentiating Gleason score (GS) 3 + 3 from GS > 3 + 3 tumors, the AUCs were 0.92 for 2D and 0.92 for 3D ROIs (p = 0.649). For differentiating GS ≤ 3 + 4 from GS ≥ 4 + 3 tumors, the AUCs were 0.70 for 2D and 0.67 for 3D ROIs (p = 0.004).
CONCLUSION: Use of a 3D ROI did not improve intrareader or interreader reproducibility or diagnostic performance compared with use of a 2D ROI for prostate ADC measurements. Interreader reproducibility of 2D ROIs was suboptimal nonetheless.
引用
- Tamada T, Huang C, Ream JM, et al. Apparent Diffusion Coefficient Values of Prostate Cancer: Comparison of 2D and 3D ROIs. AJR Am J Roentgenol. 2017. PMID: 29045185. doi:10.2214/AJR.17.18495
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。