磁共振弹性成像与声辐射力脉冲弹性成像对肝细胞癌患者肝纤维化术前分期的诊断性能前瞻性比较
前瞻性纳入77例拟行肝细胞癌肝切除术患者,同日行磁共振弹性成像与声辐射力脉冲弹性成像检查,以METAVIR病理评分为参考标准。磁共振弹性成像与纤维化分期的相关性优于声辐射力脉冲弹性成像,对显著纤维化(F≥2)的AUROC分别为0.93和0.81。磁共振弹性成像在评估晚期纤维化和肝硬化方面比声辐射力脉冲弹性成像更准确。
要点
- 磁共振弹性成像以3.0 kPa为阈值诊断F≥2的AUROC为0.93,声辐射力脉冲弹性成像以1.77 m/s为阈值AUROC为0.81。
- 磁共振弹性成像与纤维化分期的相关性为优,声辐射力脉冲弹性成像为良。
- 磁共振弹性成像对F2、F3、F4的诊断性能均优于声辐射力脉冲弹性成像。
核心结论
- 磁共振弹性成像在评估晚期纤维化和肝硬化方面是比声辐射力脉冲弹性成像更准确的影像学方法。
研究设计与样本
- 前瞻性研究,纳入77例拟行肝细胞癌肝切除术患者,同日行磁共振弹性成像和声辐射力脉冲弹性成像检查,以切除标本METAVIR评分作为参考标准,用ROC分析评估诊断性能。
诊断标准与关键数值
- 磁共振弹性成像诊断F≥2的最佳阈值为3.0 kPa,AUROC为0.93。
- 声辐射力脉冲弹性成像诊断F≥2的最佳阈值为1.77 m/s,AUROC为0.81。
- 最佳阈值以约登指数最高为选择标准。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The purpose of this study was to compare the diagnostic accuracy of magnetic resonance (MR) elastography with that of acoustic radiation force impulse (ARFI) elastography for pre-operative staging of hepatic fibrosis in patients with hepatocellular carcinoma. We prospectively enrolled 77 patients who were scheduled to undergo hepatectomy for hepatocellular carcinoma. Pre-operative MRE and ARFI elastography examinations were performed on the same day, and liver stiffness/velocity values were determined. Fibrosis stage and necro-inflammatory activity of resected specimens were determined histopathologically using the METAVIR scoring system. Correlations between MRE and ARFI elastography findings and histologic findings were determined by receiver operating characteristic (ROC) analysis. Correlation of MRE was excellent and correlation of ARFI elastography was good with fibrosis stage. MRE had better diagnostic performance than ARFI elastography in estimating substantial fibrosis (F2), severe fibrosis (F3) and cirrhosis (F4). The optimal cutoff value and the area under the ROC curve (AUROC) were determined using ROC curve analysis. The highest Youden index was used as a criterion for selecting the optimal cutoff value. ROC analysis revealed that MRE discriminated advanced stages of fibrosis (F ≥ 2) well in patients with hepatocellular carcinoma at a cutoff value of 3.0 kPa with an AUROC value of 0.93, and ARFI elastography did so at a cutoff value of 1.77 m/s with an AUROC value of 0.81 for predicting advanced stages of fibrosis (F ≥ 2). In conclusion, MRE is a more accurate imaging modality than ARFI elastography in estimating advanced stages of fibrosis and cirrhosis.
引用
- Chou CT, Chen RC, Wu WP, et al. Prospective Comparison of the Diagnostic Performance of Magnetic Resonance Elastography with Acoustic Radiation Force Impulse Elastography for Pre-operative Staging of Hepatic Fibrosis in Patients with Hepatocellular Carcinoma. Ultrasound Med Biol. 2017. PMID: 28965721. doi:10.1016/j.ultrasmedbio.2017.08.1879
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。