钆塞酸增强肝胆期MRI上低信号结节:时间反转梯度回波序列T2增强自旋回波成像的鉴别诊断初探
本研究先在体模中优化T2FFE序列的翻转角,发现50°时图像质量优于80°;随后在32例患者中比较囊肿、血管瘤、肝细胞癌和转移瘤在肝胆期的病灶-肝对比比,发现T2FFE将良性病变显示为高信号、多数恶性病变显示为低信号,差异有统计学意义。
要点
- T2FFE序列翻转角50°时图像质量评分显著优于80°(p<0.05)。
- 肝胆期T2FFE上良性病变相对肝实质呈高信号,多数恶性病变呈低信号。
- T2FFE有助于鉴别钆塞酸增强MRI肝胆期低信号结节的良恶性。
核心结论
- 钆塞酸增强MRI肝胆期的T2FFE序列有助于鉴别肝脏良恶性病变。
研究设计与样本
- 先具体模实验比较不同翻转角的信噪比,再用10例患者图像比较20°、50°和80°翻转角的肝-肌对比比及图像质量,最后在32例患者中评估优化翻转角T2FFE对肝胆期低信号结节的鉴别价值。
关键影像表现/征象
- T2FFE图像上良性病变相对肝实质呈高信号,多数恶性病变呈低信号(p<0.05)。
诊断标准与关键数值
- 信噪比随翻转角增大而升高,但在50°及以上趋于平稳。
- 翻转角50°的图像质量评分显著优于80°(p<0.05)。
临床应用与阅片要点
- 肝胆期发现低信号结节时,可结合T2FFE序列观察病灶-肝对比比以辅助鉴别良恶性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To optimize the flip angle (FA) of the T2 enhanced spin-echo imaging using the time reversed gradient echo (T2FFE) and evaluate its utility for differentiating hypointensity nodules in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced (Gd-EOB) MRI.
MATERIALS AND METHODS: First, FA optimization of the T2FFE in the HBP was investigated by comparing signal-to-noise ratio (SNR) among different FAs using phantoms. The liver-to-muscle contrast ratios (CRLiver-Muscle) and image quality among three FAs (20°, 50° and 80°) were compared using images of 10 patients. Next, the utility of the T2FFE with an optimized FA for differentiating hypointensity nodules in the HBP was assessed by comparing the lesion-to-liver contrast ratio (CRLesion-Liver) among cysts, hemangiomas, hepatocellular carcinomas, and metastatic tumors in 32 patients.
RESULTS: SNR increased as FA increased, but leveled off at FAs of 50° and greater. The FA of 50° showed significantly better image quality scores than that of 80° (p<0.05). After employing an FA of 50°, the CRLesion-Liver value indicated that the T2FFE depicted benign lesions as hyperintense and most malignant lesions as hypointense in relation with the liver parenchyma (p<0.05).
CONCLUSION: The T2FFE in the HBP of Gd-EOB-MRI is useful for differentiating benign and malignant liver lesions.
引用
- Yoneyama M, Takayama Y, Nishie A, et al. Differentiation of hypointense nodules on gadoxetic acid-enhanced hepatobiliary-phase MRI using T2 enhanced spin-echo imaging with the time-reversed gradient echo sequence: An initial experience. Eur J Radiol. 2017. PMID: 28987688. doi:10.1016/j.ejrad.2017.08.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。