文献速递腹部技术与安全CT

双层探测器双能CT用于50%碘负荷多期肝脏CT:与120 kVp协议的配对比较

Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol.
PubMed 文献 · Eur Radiol · 2017-10-23

本研究纳入45例肾功能不全成人,行双层探测器双能CT(DL-DECT)多期肝脏CT,碘负荷300 mgI/kg,生成40–70 keV虚拟单能图像(VMI);对照组为45例匹配患者,接受标准120 kVp协议(600 mgI/kg,迭代重建)。结果显示DL-DECT组SSDE显著更低(p<0.01),40–55 keV VMI的图像质量和病灶可见度与120 kVp相当或更优,且不增加辐射剂量。

要点

  • DL-DECT在50%碘负荷下,40–55 keV VMI的图像质量与病灶可见度与标准120 kVp协议相当或更优。
  • DL-DECT组SSDE显著低于120 kVp组(p<0.01),且未增加辐射剂量。
  • 40 keV图像在肝动脉期最大化肝细胞癌的可见度。

核心结论

  • 对于50%碘负荷的多期肝脏CT,DL-DECT的40–55 keV VMI在不增加辐射剂量的情况下,提供与标准120 kVp协议相当或更好的图像质量和病灶可见度。

研究设计与样本

  • 配对比较研究,纳入45例肾功能不全成人行DL-DECT(300 mgI/kg)并生成40–70 keV VMI,对照组为45例匹配患者行标准120 kVp协议(600 mgI/kg,迭代重建)。

诊断标准与关键数值

  • DL-DECT-VMI图像噪声在各keV下几乎恒定(差异≤15%),且等于或低于120 kVp;随着能量降低,CT衰减值和CNR逐渐增加,55–60 keV图像的数值与标准120 kVp几乎相当;总体质量和病灶可见度最高评分在40 keV,其次为45–55 keV,均与120 kVp相似或更好。

临床应用与阅片要点

  • 在50%碘负荷的多期肝脏CT中,DL-DECT的40–55 keV VMI可提供与标准120 kVp协议相当或更好的图像质量和病灶可见度,且SSDE显著更低(p<0.01);40 keV图像在肝动脉期最大化肝细胞癌的可见度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the image quality and lesion conspicuity of virtual-monochromatic-imaging (VMI) with dual-layer DECT (DL-DECT) for reduced-iodine-load multiphasic-hepatic CT.

METHODS: Forty-five adults with renal dysfunction who had undergone hepatic DL-DECT with 300-mgI/kg were included. VMI (40-70-keV, DL-DECT-VMI) was generated at each enhancement phase. As controls, 45 matched patients undergoing standard 120-kVp protocol (120-kVp, 600-mgI/kg, and iterative reconstruction) were included. We compared the size-specific dose estimate (SSDE), image noise, CT attenuation, and contrast-to-noise ratio (CNR) between protocols. Two radiologists scored the image quality and lesion conspicuity.

RESULTS: SSDE was significantly lower in DL-DECT group (p < 0.01). Image noise of DL-DECT-VMI was almost constant at each keV (differences of ≤15%) and equivalent to or lower than of 120-kVp. As the energy decreased, CT attenuation and CNR gradually increased; the values of 55-60 keV images were almost equivalent to those of standard 120-kVp. The highest scores for overall quality and lesion conspicuity were assigned at 40-keV followed by 45 to 55-keV, all of which were similar to or better than of 120-kVp.

CONCLUSIONS: For multiphasic-hepatic CT with 50% iodine-load, DL-DECT-VMI at 40- to 55-keV provides equivalent or better image quality and lesion conspicuity without increasing radiation dose compared with standard 120-kVp protocol.

KEY POINTS: • 40-55-keV yields optimal image quality for half-iodine-load multiphasic-hepatic CT with DL-DECT. • DL-DECT protocol decreases radiation exposure compared with 120-kVp scans with iterative reconstruction. • 40-keV images maximise conspicuity of hepatocellular carcinoma especially at hepatic-arterial phase.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Nagayama Y, Nakaura T, Oda S, et al. Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol. Eur Radiol. 2017. PMID: 29063254. doi:10.1007/s00330-017-5114-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。