文献速递腹部MR

计算扩散加权MR成像用于显示胰腺腺癌:与直接采集扩散加权成像的比较

Computed diffusion-weighted MR imaging for visualization of pancreatic adenocarcinoma: Comparison with acquired diffusion-weighted imaging.
PubMed 文献 · Eur J Radiol · 2017-07-29

本研究纳入63例胰腺腺癌患者,比较计算DWI(cDWI)与直接采集DWI显示肿瘤的效果。cDWI1500上清晰高信号肿瘤出现率显著高于DWI1000(P=0.013),与DWI1500无显著差异(P>0.999);cDWI2000低于DWI2000(P=0.028)。cDWI图像质量低于对应b值DWI,但肿瘤与远端胰腺对比度更高。作者认为cDWI1500比DWI1000更有效,至少与DWI1500相当。

要点

  • cDWI1500显示胰腺腺癌清晰高信号的比例显著高于DWI1000(P=0.013)。
  • cDWI1500与DWI1500显示清晰高信号肿瘤的比例无显著差异(P>0.999)。
  • cDWI图像质量低于对应b值直接采集DWI,但肿瘤与远端胰腺对比度更高。

核心结论

  • 由b=0和1000 s/mm²生成的cDWI1500应被认为比DWI1000更有效,且至少与DWI1500同样有效。

研究设计与样本

  • 纳入63例胰腺腺癌患者,行b=0、1000、1500、2000 s/mm²的直接DWI,并由b=0和1000 s/mm²生成cDWI1500和cDWI2000,比较肿瘤表现、图像质量和肿瘤与胰腺对比度。

关键影像表现/征象

  • 清晰高信号肿瘤在DWI1000上35例、DWI1500上50例、cDWI1500上50例、DWI2000上53例、cDWI2000上44例。
  • cDWI1500清晰高信号肿瘤出现率显著高于DWI1000(P=0.013)。
  • DWI1500与cDWI1500清晰高信号肿瘤出现率无显著差异(P>0.999)。
  • cDWI2000清晰高信号肿瘤出现率低于DWI2000(P=0.028)。
  • cDWI图像质量在b=1500(P=0.002)和b=2000 s/mm²(P<0.001)均低于对应DWI。

诊断标准与关键数值

  • 肿瘤DWI表现分为清晰高信号、远端边界不清的高信号和等信号三类。
  • cDWI2000肿瘤与远端胰腺对比度显著高于cDWI1500(P<0.001),cDWI1500显著高于DWI1000(P<0.001)。
  • cDWI肿瘤与远端胰腺对比度在b=1500(P=0.004)和b=2000 s/mm²(P<0.001)均显著高于对应DWI。

临床应用与阅片要点

  • cDWI1500由b=0和1000 s/mm²生成,显示胰腺腺癌清晰高信号的比例高于DWI1000,与DWI1500无显著差异。
  • cDWI图像质量低于直接采集DWI,但肿瘤与远端胰腺对比度更高。
  • 作者结论认为cDWI1500比DWI1000更有效,且至少与DWI1500同样有效。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the feasibility of computed diffusion-weighted imaging (cDWI) in comparison with directly acquired DWI for visualizing pancreatic adenocarcinomas.

MATERIALS AND METHODS: Patients with pancreatic adenocarcinoma underwent DWI at b-values of 0, 1000 (DWI1000), 1500 (DWI1500) and 2000 (DWI2000) s/mm2. From DWIs at b-values of 0 and 1000s/mm2, we generated cDWIs at b-values of 1500 (cDWI1500) and 2000 (cDWI2000) s/mm2. DWI findings of pancreatic adenocarcinomas (clear hyperintensity; hyperintensity with an unclear distal border; and isointensity), the image quality and the tumor to pancreas contrast ratio (CR) were compared between directly acquired DWI and cDWI.

RESULTS: Among the 63 included patients, clear hyperintense tumors were seen in 35 on DWI1000, 50 on DWI1500, 50 on cDWI1500, 53 on DWI2000 and 44 on cDWI2000. Incidence of clear hyperintense tumors was significantly higher on cDWI1500 than on DWI1000 (P=0.013). There was no significant difference in the incidence of clear hyperintense tumors between DWI1500 and cDWI1500 (P>0.999), but a lower incidence was seen on cDWI2000 than on DWI2000 (P=0.028). Image quality was lower on cDWI than on DWI at b-values of 1500 (P=0.002) and 2000s/mm2 (P<0.001). The tumor to distal pancreas CR was significantly higher on cDWI2000 than on cDWI1500 (P<0.001), and on cDWI1500 than on DWI1000 (P<0.001). The cDWI showed a significantly higher tumor to distal pancreas CR than DWI at b-values of 1500 (P=0.004) and 2000s/mm2 (P<0.001).

CONCLUSIONS: cDWI1500 generated from b-values of 0 and 1000s/mm2 should be considered more effective than DWI1000 and at least as effective as DWI1500.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Fukukura Y, Kumagae Y, Hakamada H, et al. Computed diffusion-weighted MR imaging for visualization of pancreatic adenocarcinoma: Comparison with acquired diffusion-weighted imaging. Eur J Radiol. 2017. PMID: 28987696. doi:10.1016/j.ejrad.2017.07.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。