自旋回波平面成像与三维反演重建磁共振弹性成像鉴别胰腺良恶性实性肿块的前瞻性研究
前瞻性连续纳入85例经组织病理学确诊的胰腺实性肿块患者,用自旋回波平面成像与三维反演重建的MRE测量肿块硬度与硬度比,并与血清CA19-9比较鉴别良恶性及胰腺导管腺癌与肿块型胰腺炎的能力。硬度比鉴别良恶性及PDAC与MFP的AUC分别为0.912和0.955,均优于肿块硬度与CA19-9。
要点
- 硬度比鉴别良恶性实性胰腺肿块的AUC为0.912,优于肿块硬度0.845和CA19-9的0.702。
- 硬度比鉴别PDAC与MFP的AUC为0.955,优于肿块硬度0.882和CA19-9的0.745。
- 硬度比鉴别PDAC与MFP的敏感度、特异度和准确度均高于0.9。
核心结论
- MRE基于肿块机械特性,为无创鉴别PDAC与MFP提供了有效且定量的手段。
研究设计与样本
- 前瞻性、连续性、为期24个月的研究,纳入85例经组织病理学检查确诊的胰腺实性肿块患者。
- 采用磁共振弹性成像(MRE),序列为自旋回波平面成像,并行三维反演重建,评估肿块硬度及硬度比(肿块硬度与胰腺实质硬度之比)。
- 以组织病理学检查为参考标准,计算ROC曲线下面积(AUROC)评价诊断准确性。
诊断标准与关键数值
- 鉴别恶性与良性肿块:硬度比AUC 0.912 vs 肿块硬度0.845 vs 血清CA19-9 0.702(P=0.026,P<0.001)。
- 鉴别PDAC与MFP:硬度比AUC 0.955 vs 肿块硬度0.882 vs 血清CA19-9 0.745(P=0.026,P=0.003)。
- 硬度比鉴别PDAC与MFP的敏感度、特异度和准确度均高于0.9。
临床应用与阅片要点
- 作者建议将三维MRE纳入标准MRI检查方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine the diagnostic performance of MR elastography (MRE) and compare it with serum CA19-9 in differentiating malignant from benign pancreatic masses, with emphasis on differentiating between pancreatic ductal adenocarcinoma (PDAC) and mass-forming pancreatitis (MFP).
METHODS: We performed a prospective, consecutive, 24-month study in 85 patients with solid pancreatic masses confirmed by histopathologic examinations. The mass stiffness and stiffness ratio (calculated as the ratio of mass stiffness to the parenchymal stiffness) were assessed. The diagnostic accuracy was analysed by calculating the area under the ROC curve (AUROC).
RESULTS: The final diagnosis included 54 malignant tumours (43 patients with PDAC) and 31 benign masses (24 patients with MFP). The stiffness ratio showed better diagnostic performance than the mass stiffness and serum CA19-9 for the differentiation between malignant and benign masses (AUC: 0.912 vs. 0.845 vs. 0.702; P = 0.026, P < 0.001) and, specifically, between PDAC and MFP (AUC: 0.955 vs. 0.882 vs. 0.745; P = 0.026, P = 0.003). The sensitivity, specificity, and accuracy of stiffness ratio for the differentiation of PDAC and MFP were all higher than 0.9.
CONCLUSIONS: MRE presents an effective and quantitative strategy for non-invasive differentiation between PDAC and MFP based on their mechanical properties.
KEY POINTS: • 3D MRE is useful for calculating stiffness of solid pancreatic tumours. • Stiffness ratio outperformed stiffness and CA19-9 for differentiating PDAC from MFP. • Incorporation of 3D MRE into a standard MRI protocol is recommended.
引用
- Shi Y, Gao F, Li Y, et al. Differentiation of benign and malignant solid pancreatic masses using magnetic resonance elastography with spin-echo echo planar imaging and three-dimensional inversion reconstruction: a prospective study. Eur Radiol. 2017. PMID: 28986646. doi:10.1007/s00330-017-5062-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。