低kV与双能虚拟单能CT成像对已证实肝脏病灶的对比:在病灶显著性和图像质量上的优势与取舍——一项初步研究
纳入31例患者72个已证实肝脏病灶,比较半剂量单能低管电压(SE-LTP)与双能虚拟单能(DE-VM)图像。DE-VM在40、45、50 keV时病灶显著性评分优于其他半剂量图像集(p<0.0001),但SE-LTP噪声和伪影更少、更锐利,放射科医师整体更偏好SE-LTP图像(p<0.0001)。
要点
- 半剂量DE-VM在40–50 keV时肝脏病灶显著性评分最高(p<0.0001)。
- SE-LTP与DE-VM的病灶诊断信心相似(p≥0.05)。
- SE-LTP噪声和伪影更少、更锐利,医师整体更偏好SE-LTP。
核心结论
- 在相同应用剂量水平下,DE-VM较SE-LTP显示肝脏病灶更显著,但SE-LTP图像因噪声和伪影更低而比任何单一DE-VM能量水平更受偏好。
研究设计与样本
- 初步研究,31例患者72个已证实肝脏病灶(21个良性、51个恶性),行全剂量对比增强双能CT,半剂量图像通过单管重建双源SE-LTP投影数据(80或100 kV)及向双能投影数据插入噪声获得,DE-VM图像重建40至70 keV。
关键影像表现/征象
- 半剂量DE-VM在40、45、50 keV的病灶显著性平均评分优于其他半剂量图像集(p<0.0001)。
- SE-LTP图像较低于70 keV的DE-VM图像噪声和伪影更少且更锐利(p<0.05)。
- 按患者计算,放射科医师最偏好SE-LTP图像,最不偏好40–50 keV(p<0.0001)。
诊断标准与关键数值
- 病灶诊断信心采用4分制逐病灶评分,半剂量SE-LTP与半剂量DE-VM相似(p≥0.05;1.19 vs. 1.24–1.32)。
- 病灶-肝脏对比噪声比(CNR)在SE-LTP图像中高于DE-VM图像(p<0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Single-energy low tube potential (SE-LTP) and dual-energy virtual monoenergetic (DE-VM) CT images both increase the conspicuity of hepatic lesions by increasing iodine signal. Our purpose was to compare the conspicuity of proven liver lesions, artifacts, and radiologist preferences in dose-matched SE-LTP and DE-VM images.
METHODS: Thirty-one patients with 72 proven liver lesions (21 benign, 51 malignant) underwent full-dose contrast-enhanced dual-energy CT (DECT). Half-dose images were obtained using single tube reconstruction of the dual-source SE-LTP projection data (80 or 100 kV), and by inserting noise into dual-energy projection data, with DE-VM images reconstructed from 40 to 70 keV. Three blinded gastrointestinal radiologists evaluated half-dose SE-LTP and DE-VM images, ranking and grading liver lesion conspicuity and diagnostic confidence (4-point scale) on a per-lesion basis. Image quality (noise, artifacts, sharpness) was evaluated, and overall image preference was ranked on per-patient basis. Lesion-to-liver contrast-to-noise ratio (CNR) was compared between techniques.
RESULTS: Mean lesion size was 1.5 ± 1.2 cm. Across the readers, the mean conspicuity ratings for 40, 45, and 50 keV half-dose DE-VM images were superior compared to other half-dose image sets (p < 0.0001). Per-lesion diagnostic confidence was similar between half-dose SE-LTP compared to half-dose DE-VM images (p ≥ 0.05; 1.19 vs. 1.24-1.32). However, SE-LTP images had less noise and artifacts and were sharper compared to DE-VM images less than 70 keV (p < 0.05). On a per-patient basis, radiologists preferred SE-LTP images the most and preferred 40-50 keV the least (p < 0.0001). Lesion CNR was also higher in SE-LTP images than DE-VM images (p < 0.01).
CONCLUSION: For the same applied dose level, liver lesions were more conspicuous using DE-VM compared to SE-LTP; however, SE-LTP images were preferred more than any single DE-VM energy level, likely due to lower noise and artifacts.
引用
- Hanson GJ, Michalak GJ, Childs R, et al. Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study. Abdom Radiol (NY). 2018. PMID: 28983661. doi:10.1007/s00261-017-1327-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。