文献速递腹部CTMR

双能CT物质密度碘图检测和表征富血供肝脏病灶:与磁共振成像对比

Material density iodine images in dual-energy CT: Detection and characterization of hypervascular liver lesions compared to magnetic resonance imaging.
PubMed 文献 · Eur J Radiol · 2017-08-31

研究纳入52例患者共236个富血供肝脏病灶,对比双能CT物质密度碘图与65keV单能图像,以MRI为标准。碘图的肝脏-病灶比和对比噪声比均显著高于65keV图像和MRI,三位阅片者检出病灶数更多,但良恶性分类无显著差异,有经验阅片者诊断信心更高。结论认为碘图有助于提高富血供肝脏病灶的显著性和检出。

要点

  • 物质密度碘图的肝脏-病灶比和对比噪声比显著高于65keV单能图像和MRI。
  • 三位阅片者用碘图检出的病灶数均多于65keV图像(83.13% vs 63.64%等)。
  • 碘图与65keV图像在病灶良恶性分类上无显著差异。

核心结论

  • 双能CT物质密度碘图有助于提高富血供肝脏病灶的显著性和检出。

研究设计与样本

  • 研究遵循HIPAA指南并经机构审查委员会批准,纳入52例患者(男36例、女16例,年龄29-87岁)共236个富血供肝脏病灶(良性31个、恶性205个,平均直径29.4mm,范围6-90.6mm),所有患者均在三个月内接受对比增强单源双能CT和对比增强腹部MRI检查;晚期动脉期CT采用140和80kVp双能量采集,方案A为65keV单能图像,方案B为物质密度碘图,三位放射科医师对随机化图像进行定性评估。

诊断标准与关键数值

  • 肝脏-病灶比在方案B为2.8±2.33,显著高于方案A的0.77±0.55和MRI的0.61±0.66;对比噪声比在方案B为0.08±0.04,显著高于方案A的0.01±0.01和MRI的0.01±0.01;三位阅片者用方案B正确识别的病灶数均多于方案A:83.13% vs 63.64%、84.57% vs 68.09%、79.37% vs 65.52%。

临床应用与阅片要点

  • 作者结论认为双能CT物质密度碘图有助于提高富血供肝脏病灶的显著性和检出,三位阅片者用碘图检出的病灶数均多于65keV图像,但良恶性分类无显著差异,有经验阅片者使用碘图时报告更高诊断信心的频率更高(84.6% vs 75%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the diagnostic potential of Material Density (MD) iodine images in dual-energy CT (DECT) for the detection and characterization of hypervascular liver lesions compared to monenergetic 65keV images, using MRI as the standard.

MATERIALS AND METHODS: The study complied with HIPAA guidelines and was approved by the institutional review board. Fifty-two patients (36 men, 16 women; age range, 29-87 years) with 236 hypervascular liver lesions (benign, n=31; malignant, n=205; mean diameter, 29.4mm; range: 6-90.6mm) were included. All of them underwent both contrast-enhanced single-source DECT and contrast-enhanced abdominal MRI within three months. Late arterial phase CT imaging was performed with dual energies of 140 and 80kVp. Protocol A showed monoenergetic 65keV images, and protocol B presented MD-iodine images. Three radiologists qualitatively evaluated randomized images, and lesion detection, characterization, and reader confidence were recorded. Liver-to-lesion ratio (LLR) and contrast-to-noise ratio (CNR) were assessed on protocol A, protocol B, and MRI. Paired t-tests were used to compare LLR, CNR, and the number of detected lesions.

RESULTS: LLR was significantly increased in protocol B (2.8±2.33) compared to protocol A (0.77±0.55) and MRI (0.61±0.66). CNR was significantly higher in protocol B (0.08±0.04) compared to protocol A (0.01±0.01) and MRI (0.01±0.01). All three observers correctly identified more liver lesions using protocol B vs protocol A: 83.13% vs 63.64%, 84.57% vs 68.09%, and 79.37% vs 65.52%. There was no significant difference between the three observers in classification of a lesion as benign or malignant. However, higher diagnostic confidence was reported more frequently by the experienced radiologist when using protocol B vs protocol A (84.6% vs 75%).

CONCLUSION: MD-iodine images in DECT help to increase the conspicuity and detection of hypervascular liver lesions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Muenzel D, Lo GC, Yu HS, et al. Material density iodine images in dual-energy CT: Detection and characterization of hypervascular liver lesions compared to magnetic resonance imaging. Eur J Radiol. 2017. PMID: 28987684. doi:10.1016/j.ejrad.2017.08.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。