文献速递外周血管腹部CT

计算机断层扫描分辨率对区分腹主动脉瘤壁组织与钙化的影响:一项概念验证研究

On the effect of computed tomography resolution to distinguish between abdominal aortic aneurysm wall tissue and calcification: A proof of concept.
PubMed 文献 · Eur J Radiol · 2017-08-26

研究采用8例开放手术腹主动脉瘤壁样本,以扫描电镜为参考、micro-CT在15.5–155μm分辨率范围扫描,评估分辨率降低对组织与钙化面积测量的影响。155μm分辨率可显著预测参考面积测量(r=0.850/0.999),组织与钙化面积误差分别为8.8%±1.86和26.13%±9.40,敏感度87.17%。作者认为高分辨率CT纳入瘤壁测量可能有助于改进破裂风险评估。

要点

  • 破裂腹主动脉瘤壁外层组织在径向分布上极薄,厚度小于200μm。
  • 155μm分辨率可显著预测参考的组织与钙化面积测量(r=0.850与r=0.999,均p<0.001)。
  • 155μm分辨率下组织面积误差8.8%±1.86、钙化面积误差26.13%±9.40,敏感度87.17%。

核心结论

  • 纳入高分辨率CT的腹主动脉瘤壁测量可阐明瘤壁组织与钙化分布差异,可能有助于改进破裂风险评估。

研究设计与样本

  • 概念验证研究,取8例开放手术腹主动脉瘤壁样本,扫描电镜为参考,micro-CT在15.5–155μm分辨率范围扫描,并与多排CT分辨率744μm比较。

关键影像表现/征象

  • 破裂腹主动脉瘤电镜显示径向分布极薄的外层组织,厚度小于200μm。
  • 该薄层组织支撑瘤壁,邻近中膜钙化面积远大于组织层面积。

诊断标准与关键数值

  • 155μm分辨率对参考瘤壁组织面积测量r=0.850、p<0.001,对钙化面积r=0.999、p<0.001。
  • 155μm分辨率下组织面积误差8.8%±1.86、钙化面积误差26.13%±9.40,敏感度87.17%。
  • 参考分辨率为15.5μm,多排CT分辨率为744μm。

临床应用与阅片要点

  • 作者认为,通过高分辨率CT纳入腹主动脉瘤壁测量可能有助于改进破裂风险评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study is to determine the optimal target CT spatial resolution for accurately imaging abdominal aortic aneurysm (AAA) wall characteristics, distinguishing between tissue and calcification components, for an accurate assessment of rupture risk.

MATERIALS AND METHODS: Ruptured and non-ruptured AAA-wall samples were acquired from eight patients undergoing open surgical aneurysm repair upon institutional review board approval and informed consent was obtained from all patients. Physical measurements of AAA-wall cross-section were made using scanning electron microscopy. Samples were scanned using high resolution micro-CT scanning. A resolution range of 15.5-155μm was used to quantify the influence of decreasing resolution on wall area measurements, in terms of tissue and calcification. A statistical comparison between the reference resolution (15.5μm) and multi-detector CT resolution (744μm) was also made.

RESULTS: Electron microscopy examination of ruptured AAAs revealed extremely thin outer tissue structure <200μm in radial distribution which is supporting the aneurysm wall along with large areas of adjacent medial calcifications far greater in area than the tissue layer. The spatial resolution of 155μm is a significant predictor of the reference AAA-wall tissue and calcification area measurements (r=0.850; p<0.001; r=0.999; p<0.001 respectively). The tissue and calcification area at 155μm is correct within 8.8%±1.86 and 26.13%±9.40 respectively with sensitivity of 87.17% when compared to the reference.

CONCLUSION: The inclusion of AAA-wall measurements, through the use of high resolution-CT will elucidate the variations in AAA-wall tissue and calcification distributions across the wall which may help to leverage an improved assessment of AAA rupture risk.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Barrett HE, Cunnane EM, O Brien JM, et al. On the effect of computed tomography resolution to distinguish between abdominal aortic aneurysm wall tissue and calcification: A proof of concept. Eur J Radiol. 2017. PMID: 28987694. doi:10.1016/j.ejrad.2017.08.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。