使用首过分析动态CT灌注综合评估冠状动脉疾病:在猪模型中的验证

Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.
PubMed 文献 · Radiology · 2017-10-23

本研究在6只猪模型中回顾性验证一种将CT血管成像与动态CT灌注测量合并为一次低剂量检查的首过分析(FPA)技术,于左前降支制造4至5处中等严重度狭窄,每处狭窄采集20次增强容积扫描。FPA与最大斜率模型灌注测量均与微球灌注参考标准相关,FPA合并三支冠状动脉的回归为PFPA_COMBINED=1.02 PMICRO_COMBINED+0.11(r=0.96),MSM为PMSM_COMBINED=0.28 PMICRO_COMBINED+0.23(r=0.89);每次两容积FPA灌注测量的CT剂量指数和体型特异性剂量估计分别为10.8和17.8 mGy。

要点

  • FPA技术将CT血管成像与动态CT灌注合并为一次低剂量检查,在猪模型中回顾性验证。
  • FPA合并三支冠状动脉灌注与微球参考标准高度相关(r=0.96),优于MSM(r=0.89)。
  • 每次两容积FPA灌注测量的CT剂量指数为10.8 mGy,体型特异性剂量估计为17.8 mGy。

核心结论

  • FPA技术在猪模型中获回顾性验证,有潜力用于冠状动脉疾病的准确、低剂量、血管特异性形态与生理评估。

研究设计与样本

  • 回顾性动物验证研究,于2015年4月至2016年10月在6只猪(平均体重37.3 kg±7.5)中进行,于左前降支制造4至5处中等严重度狭窄,每处狭窄采集20次增强容积扫描,以微球灌注测量为参考标准。

诊断标准与关键数值

  • FPA合并三支冠状动脉灌注与微球参考标准的回归为PFPA_COMBINED=1.02 PMICRO_COMBINED+0.11(r=0.96)。
  • MSM合并三支冠状动脉灌注与微球参考标准的回归为PMSM_COMBINED=0.28 PMICRO_COMBINED+0.23(r=0.89)。
  • 每次两容积FPA灌注测量的CT剂量指数为10.8 mGy,体型特异性剂量估计为17.8 mGy。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (PFPA and PMSM) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (PMICRO), as follows: PFPA_COMBINED = 1.02 PMICRO_COMBINED + 0.11 (r = 0.96) and PMSM_COMBINED = 0.28 PMICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.

来源:Radiology,查看原文。版权归原作者所有。