PubMed 文献 · Br J Radiol · 2017-10-27

研究纳入16例患者共22枚冠状动脉支架,行320层冠状动脉CT血管造影,分别用混合迭代重建(AIDR 3D)和基于模型的迭代重建(FIRST)重建图像,以有创冠状动脉造影为参考标准。FIRST较AIDR 3D降低了支架管腔衰减增加比(0.20 vs 0.32)、提高了可见支架管腔直径比(52.5% vs 47.5%),并将诊断支架内再狭窄(≥50%)的敏感度由60%提高至100%、准确率由86.4%提高至95.5%,两种重建方法特异度均为94.1%。作者认为基于模型的迭代重建算法可能改善支架内再狭窄的检出。

要点

  • FIRST重建较AIDR 3D降低支架管腔衰减增加比(0.20 vs 0.32),减轻线束硬化伪影。
  • FIRST较AIDR 3D提高可见支架管腔直径比(52.5% vs 47.5%),支架管腔显示更充分。
  • FIRST诊断支架内再狭窄敏感度100%、准确率95.5%,均高于AIDR 3D的60%和86.4%。

核心结论

  • 基于模型的迭代重建算法可能改善冠状动脉CT血管造影对支架内再狭窄(≥50%)的诊断性能。

研究设计与样本

  • 单中心初步经验研究,纳入16例患者共22枚冠状动脉支架,采用320层CT行冠状动脉CT血管造影,图像分别以混合迭代重建(AIDR 3D)和基于模型的迭代重建(FIRST)重建,以有创冠状动脉造影为参考标准。

关键影像表现/征象

  • FIRST重建图像上支架管腔衰减增加比为0.20,低于AIDR 3D图像的0.32。
  • FIRST重建图像上可见支架管腔直径与真实支架管腔直径之比为52.5%,高于AIDR 3D图像的47.5%。
  • 作者指出与混合迭代重建相比,基于模型的迭代重建减少了 Blooms 伪影并改善了图像质量。

诊断标准与关键数值

  • 以有创冠状动脉造影为参考标准,支架内再狭窄定义为病变≥50%,22枚支架中5枚(22.7%)存在显著支架内再狭窄。
  • FIRST重建诊断支架内再狭窄的敏感度100%、特异度94.1%、阳性预测值83.3%、阴性预测值100%、准确率95.5%。
  • AIDR 3D重建诊断支架内再狭窄的敏感度60%、特异度94.1%、阳性预测值75.0%、阴性预测值88.9%、准确率86.4%。

临床应用与阅片要点

  • 对冠状动脉支架术后患者行冠状动脉CT血管造影时,基于模型的迭代重建(FIRST)较混合迭代重建(AIDR 3D)可减轻支架管腔衰减增加、增加可见支架管腔直径,可能有助于支架内再狭窄的检出。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of our study was to compare the diagnostic performance of coronary CT angiography (CTA) subjected to model-based iterative reconstruction (IR) or hybrid IR to rule out coronary in-stent restenosis.

METHODS: We enrolled 16 patients who harboured 22 coronary stents. They underwent coronary CTA on a 320-slice CT scanner. The images were reconstructed with hybrid IR (AIDR 3D) and model-based IR (FIRST) algorithms. We calculated the stent lumen attenuation increase ratio and measured the visible stent lumen diameter. Two blinded observers visually graded the likelihood of in-stent restenosis (lesions ≥ 50%) on hybrid IR and FIRST images.

RESULTS: The stent lumen attenuation increase ratio on FIRST- was lower than on AIDR 3D images (0.20 vs 0.32). The ratio of the visible- compared to the true stent lumen diameter was higher on FIRST- than AIDR 3D images (52.5 vs 47.5%). Invasive coronary angiography identified five stents (22.7%) with significant in-stent restenosis. The use of FIRST improved the sensitivity (60 vs 100%), positive (75.0 vs 83.3%) and negative predictive value (88.9 vs 100%) and the accuracy (86.4 vs 95.5%) for the detection of in-stent restenosis. Specificity was 94.1% for both reconstruction methods.

CONCLUSION: The model-based IR algorithm may improve diagnostic performance for the detection of in-stent restenosis. Advances in knowledge: Compared to hybrid IR, the new model-based IR algorithm reduced blooming artefacts and improved the image quality. It can be expected to improve diagnostic performance for the detection of in-stent restenosis on coronary CTA images.