文献速递心血管CTDSA

冠状动脉CT血管成像与有创冠状动脉造影不一致性病变的临床意义:聚焦导致未来心脏事件的罪犯病变

Discrepancies between coronary CT angiography and invasive coronary angiography with focus on culprit lesions which cause future cardiac events.
PubMed 文献 · Eur Radiol · 2017-10-23

在220例疑似冠心病患者中,比较256排冠状动脉CT血管成像(CCTA)与有创冠状动脉造影(ICA)对阻塞性病变(≥50%狭窄)的检出差异,并随访40个月评估主要不良心脏事件(MACE)。CCTA与ICA不一致见于3166个冠状动脉节段中的121个(3.8%),假阳性病变常见原因为钙化(45.9%)和正性重构(29.6%),假阴性病变常见原因为噪声(40.0%)和运动伪影(37.8%)。不一致病变中7个发生MACE,其中29个正性重构病变中6个(20.7%),53个钙化病变中1个(1.9%)。

要点

  • CCTA与ICA不一致节段占3.8%(121/3166),假阳性主因为钙化(45.9%)和正性重构(29.6%),假阴性主因为噪声(40.0%)和运动伪影(37.8%)。
  • 正性重构病变的MACE发生率高于钙化病变:29个正性重构病变中6个(20.7%)发生MACE,53个钙化病变中1个(1.9%)。
  • 在中间狭窄病变中,包含正性重构的CCTA相关预测值高于ICA相关预测值。

核心结论

  • 正性重构是CCTA假阳性病变中MACE的常见原因,CCTA上出现正性重构可能提示临床意义,尽管ICA可能漏诊。

研究设计与样本

  • 纵向研究,纳入220例疑似冠心病患者,均行256排CCTA和ICA,以ICA为参考标准比较阻塞性CAD(≥50%狭窄),随访40个月评估MACE。

关键影像表现/征象

  • CCTA与ICA不一致见于3166个冠状动脉节段中的121个(3.8%)。
  • 83个假阳性病变中,钙化占45.9%,正性重构占29.6%。
  • 38个假阴性病变中,噪声占40.0%,运动伪影占37.8%。
  • 不一致病变中7个发生MACE,其中29个正性重构病变中6个(20.7%)发生MACE,53个钙化病变中1个(1.9%)发生MACE。

诊断标准与关键数值

  • 以ICA为参考标准,CCTA阻塞性CAD定义为≥50%狭窄。
  • 中间狭窄病变中,包含正性重构的CCTA相关预测值高于ICA相关预测值。

临床应用与阅片要点

  • CCTA上正性重构可视为假阳性病变的常见原因,并可能提示临床意义,即使ICA未见相应阻塞。
  • CCTA阅片时应仔细观察正性重构,即使病变被判定为假阳性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the clinical significance of discrepant lesions between coronary computed tomography angiography (CCTA) and invasive coronary angiography (ICA) in a longitudinal study.

METHODS: In 220 patients with suspected coronary artery disease (CAD) who underwent both 256-row CCTA and ICA, the obstructive CAD (≥ 50% stenosis) on CCTA was compared with that on ICA as the reference standard. We analysed the causes of the discrepancy between CCTA and ICA. During a 40-month follow-up period, major adverse cardiac events (MACE) were assessed.

RESULTS: Discordance between CCTA and ICA was observed in 121 of the 3166 coronary artery segments (3.8%). Common causes were calcification (45.9%) and positive remodelling (PR) (29.6%) in 83 false positive lesions, and noise (40.0%) and motion artefact (37.8%) in 38 false negative lesions. MACE occurred in seven lesions among the discrepant lesions; six among the 29 PR lesions (20.7%) and one among the 53 calcified lesions (1.9%). With respect to the prediction power of MACE in an intermediate stenosis, the CCTA-related value including PR was higher than the ICA-related value.

CONCLUSIONS: PR was a frequent cause of MACE among the false positive lesions on CCTA. Therefore, the presence of PR on CCTA may suggest clinical significance, although it can be missed by ICA.

KEY POINTS: • Compared to ICA, PR in CCTA may be cause of false positive lesion. • CCTA-related value including PR shows higher prediction power of MACE than ICA-related value. • PR reflects atherosclerotic burden that can be related to cardiac events. • PR in CCTA should be observed carefully, even if it is false positive.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim J, Kwag HJ, Yoo SM, et al. Discrepancies between coronary CT angiography and invasive coronary angiography with focus on culprit lesions which cause future cardiac events. Eur Radiol. 2017. PMID: 29063248. doi:10.1007/s00330-017-5095-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。