接受介入性深静脉重建术患者的下肢静脉解剖显示:平衡稳态自由进动MRI的作用
本研究回顾性比较平衡稳态自由进动MRI(bSSFP-MRI)与静脉数字减影血管造影(IVDSA)在介入性深静脉重建术前评估中的价值,共纳入44例患者225个静脉节段,bSSFP-MRI诊断156个异常节段而IVDSA诊断151个,总体敏感度99.3%、特异度91.9%,支持无对比剂bSSFP-MRI作为IVDSA的准确、快速、无创替代方法。
要点
- bSSFP-MRI诊断下肢深静脉病变的总体敏感度99.3%、特异度91.9%,与IVDSA金标准高度一致。
- 髂静脉和股静脉节段病变患病率较高(范围79.6%-88.6%),是评估重点区域。
- bSSFP-MRI可准确显示拟行介入性深静脉重建术患者的病变范围和严重程度。
核心结论
- 本研究支持使用无对比剂平衡稳态自由进动MRI在介入性深静脉重建术前评估下肢深静脉,该技术是IVDSA的准确、快速、无创替代方法。
研究设计与样本
- 回顾性比较研究,纳入所有同时接受bSSFP-MRI和IVDSA检查以制定介入性深静脉重建治疗计划的患者,共44例患者225个静脉节段,由两名委员会认证放射科医生独立按预定分类系统对每个静脉节段病变严重程度进行分级,以IVDSA为金标准。
诊断标准与关键数值
- bSSFP-MRI与IVDSA比较的总体敏感度99.3%、特异度91.9%、阳性似然比12.3、阴性似然比0.007、诊断比值比1700;bSSFP-MRI诊断156个异常静脉节段,IVDSA诊断151个;髂静脉和股静脉节段病变患病率范围79.6%-88.6%。
临床应用与阅片要点
- 原文结论支持在介入性深静脉重建术前使用无对比剂bSSFP-MRI评估下肢深静脉,可作为IVDSA的准确、快速、无创替代方法。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study evaluates the use of balanced steady-state free precession MRI (bSSFP-MRI) in the diagnostic work-up of patients undergoing interventional deep venous reconstruction (I-DVR). Intravenous digital subtraction angiography (IVDSA) was used as the gold-standard for comparison to assess disease extent and severity.
METHODS: A retrospective comparison of bSSFP-MRI to IVDSA was performed in all patients undergoing both examinations for treatment planning prior to I-DVR. The severity of disease in each venous segment was graded by two board-certified radiologists working independently, according to a predetermined classification system.
RESULTS: In total, 44 patients (225 venous segments) fulfilled the inclusion criteria. A total of 156 abnormal venous segments were diagnosed using bSSFP-MRI compared with 151 using IVDSA. The prevalence of disease was higher in the iliac and femoral segments (range, 79.6-88.6%). Overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and the diagnostic ratio for bSSFP-MRI were 99.3%, 91.9%, 12.3, 0.007 and 1700, respectively.
CONCLUSION: This study supports the use of non-contrast balanced SSFP-MRI in the assessment of the deep veins of the lower limb prior to I-DVR. The technique offers an accurate, fast and non-invasive alternative to IVDSA. Advances in Knowledge: Although balanced SSFP-MRI is commonly used in cardiac imaging, its use elsewhere is limited and its use in evaluating the deep veins prior to interventional reconstruction is not described. Our study demonstrates the usefulness of this technique in the work-up of patients awaiting interventional venous reconstruction compared with the current gold standard.
引用
- Helyar VG, Gupta Y, Blakeway L, et al. Depiction of lower limb venous anatomy in patients undergoing interventional deep venous reconstruction-the role of balanced steady state free precession MRI. Br J Radiol. 2017. PMID: 29076743. doi:10.1259/bjr.20170005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。