单次20秒深吸气屏气采集在FDG PET/CT评估肺结节中的附加价值
本研究比较单次20秒深吸气屏气(DIBH)FDG PET/CT与传统自由呼吸(FB)全身PET/CT对肺病变评估的准确性。预实验19例中DIBH与相位呼吸门控(PBRG)相关性高(SUVmax r=0.94,SUVpeak r=0.98,均P<.001)。115例临床患者中,DIBH较FB显著提高SUVmax(5.60±4.20 vs 3.11±1.80)和SUVpeak(2.25±1.75 vs 1.71±0.96,均P<.001),检出更多肺病变(P<.001,额外检出70个结节,84个配准更准确),SUVpeak的ROC曲线下面积准确性更高(P=.039)。
要点
- DIBH PET/CT较FB显著提高肺病变SUVmax和SUVpeak(均P<.001)。
- DIBH较FB检出更多肺结节(P<.001,额外70个,84个配准更准确)。
- DIBH的SUVpeak ROC曲线下面积准确性高于FB(P=.039)。
核心结论
- DIBH PET/CT技术在日常临床实践中可行,对定量测量和病变定位更敏感,减少呼吸运动模糊效应,从而提高肺结节的诊断准确性。
研究设计与样本
- 预实验19例评估DIBH与PBRG的可行性和一致性;随后前瞻性纳入115例肺病变患者,行FB PET/CT后行20秒DIBH PET/CT,以组织病理学和/或临床-影像随访为参考标准。
关键影像表现/征象
- DIBH较FB显著提高SUVmax(5.60±4.20 vs 3.11±1.80,P<.001)和SUVpeak(2.25±1.75 vs 1.71±0.96,P<.001)。
- DIBH较FB检出更多肺病变(P<.001),额外检出70个结节,84个配准更准确。
诊断标准与关键数值
- 预实验DIBH与PBRG相关性:SUVmax r=0.94(P<.001),SUVpeak r=0.98(P<.001)。
- SUVpeak的ROC曲线下面积:DIBH准确性高于FB(P=.039)。
临床应用与阅片要点
- DIBH PET/CT技术在日常临床实践中可行,可减少呼吸运动模糊效应,提高肺结节定量测量和病变定位的敏感性及诊断准确性。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare the accuracy of a single 20-second deep-inspiration breath hold (DIBH) in fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) to that with conventional free-breathing (FB) whole-body PET/CT for the assessment, characterization, and quantification of lung lesions in terms of the blurring effect of respiratory motion. Materials and Methods Institutional review board approval was obtained, and the requirement to obtain informed consent was waived. A preclinical study was performed in a test population of 19 patients to evaluate the feasibility and consistency of DIBH techniques compared with phase-based respiratory gating (PBRG). One hundred fifteen patients with lung lesions were then prospectively included and assessed with FB PET/CT followed by 20-second DIBH PET/CT. Maximum standardized uptake value (SUVmax), peak standardized uptake value (SUVpeak), and number and size of nodules were reported for each acquisition and then compared with findings from histopathologic examination and/or clinical-radiologic follow-up. Statistical analysis was performed with the t test, χ2 test, Pearson correlation coefficient, and receiver operating characteristic analysis. Results In the test population, data obtained with DIBH PET and PBRG PET showed close correlation (r = 0.94, P < .001 for SUVmax and r = 0.98, P < .001 for SUVpeak). In the clinical population, both SUVmax and SUVpeak were significantly increased with DIBH compared with FB (5.60 ± 4.20 vs 3.11 ± 1.80 and 2.25 ± 1.75 vs 1.71 ± 0.96, respectively; P < .001). A significantly greater number of lung lesions was detected with DIBH PET/CT compared with FB PET/CT (P < .001), with the detection of 70 additional nodules and more accurate coregistration of 84. According to the area under the receiver operating characteristic curve for SUVpeak, DIBH demonstrated a higher level of accuracy than did FB (P = .039). Conclusion The DIBH PET/CT technique is feasible in routine clinical practice and is more sensitive for quantitative measurements and lesion localization. This technique reduces the blurring effect of respiratory motion, thus improving the diagnostic accuracy for lung nodules. © RSNA, 2017.
引用
- Balamoutoff N, Serrano B, Hugonnet F, et al. Added Value of a Single Fast 20-second Deep-Inspiration Breath-hold Acquisition in FDG PET/CT in the Assessment of Lung Nodules. Radiology. 2017. PMID: 29040022. doi:10.1148/radiol.2017160534
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。