使用专用COPD软件评估裂隙完整性对肺气肿型COPD定量CT及肺气肿分布的影响
研究纳入50例COPD患者的CT,全自动肺叶分割后手动校正,视觉评估裂隙完整性(FI),分析FI对肺气肿比率(ER)、平均肺密度(MLD)及相邻肺叶肺气肿和总体积的影响。结果显示完全与不完全裂隙相邻肺叶ER差异均无统计学意义(p>0.05),自动与手动校正分割的肺气肿结果超出临床可接受范围但不受FI显著影响(p>0.05)。结论认为FI对自动肺叶分割和肺气肿分布无显著影响,重度肺气肿仍推荐手动校正自动肺叶分割。
要点
- 完全与不完全裂隙相邻肺叶ER差异均无统计学意义(p>0.05)。
- 自动与手动校正分割的肺气肿结果超出临床可接受范围。
- 重度肺气肿仍推荐手动校正自动肺叶分割。
核心结论
- 裂隙完整性对自动肺叶分割和肺气肿分布无显著影响,重度肺气肿仍推荐手动校正自动肺叶分割。
研究设计与样本
- 研究纳入50例COPD患者的CT,由软件全自动肺叶分割并手动校正,视觉以百分比量表评估裂隙完整性,分析其对肺气肿比率(ER=密度值<-950 HU的肺容积百分比)、平均肺密度(MLD)及相邻肺叶肺气肿和总体积的影响。
诊断标准与关键数值
- 肺气肿比率ER定义为密度值<-950 HU的肺容积百分比。
- 完全与不完全裂隙相邻肺叶ER差异:右侧水平裂12.4%,右侧斜裂0.2%和3%,左侧斜裂4.4%,均p>0.05。
- 自动与手动校正分割的肺气肿结果超出临床可接受值,但不受FI显著影响(p>0.05)。
- ER和MLD最宽的界限一致性出现在右中叶(ER [-14, 17.4%],MLD [-22.4, 32.4 Hounsfield Units])。
临床应用与阅片要点
- 自动肺叶分割和肺气肿分布评估可不因裂隙完整性而显著改变。
- 重度肺气肿仍推荐手动校正自动肺叶分割。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Fissure integrity (FI) plays a key role in selecting patients for interventional emphysema therapy. We investigated its interference with automated lobar segmentation in quantitative computed tomography (CT) and emphysema distribution.
METHODS: CT was available for 50 patients with chronic obstructive pulmonary disease (COPD). Lobe segmentation was performed fully automated by software and corrected manually. FI was evaluated visually using a %-scale. The influence of FI on emphysema ratio (ER=percentage of lung volume with density values<-950 HU), mean lung density (MLD), emphysema and total volume of adjacent lobes was analyzed. Lobe-based results were compared with respect to FI.
RESULTS: Differences in ER in adjacent lobes for complete vs. incomplete fissures were 12.4% for the right horizontal, 0.2% and 3% for the right oblique and 4.4% for the left oblique fissure (all p>0.05). Results for emphysema comparing automated vs. manually corrected segmentation exceeded clinically acceptable values, but were not significantly affected by FI (p>0.05). The widest limits of agreement for ER and MLD were noted in the right middle lobe ([-14, 17.4%], [-22.4, 32.4 Hounsfield Units]).
CONCLUSIONS: Automated lobe segmentation and emphysema distribution are not significantly affected by FI. Manual correction of automated lobar segmentation is still recommended in severe emphysema.
引用
- Müller J, Lim HJ, Eichinger M, et al. Influence of fissure integrity on quantitative CT and emphysema distribution in emphysema-type COPD using a dedicated COPD software. Eur J Radiol. 2017. PMID: 28987683. doi:10.1016/j.ejrad.2017.08.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。