胸部X线剂量等效CT评估胸主动脉钙化动脉粥样硬化负荷的诊断准确性
前瞻性单中心研究纳入106例患者,在同一次检查中先行标准剂量胸部CT(1.7±0.7 mSv),再行100 kV锡滤过超低剂量CT(0.13±0.01 mSv)以达到胸部X线等效剂量。超低剂量CT检测主动脉瓣、升主动脉和主动脉弓钙化的敏感度分别为93.5%、96.2%和96.2%,胸主动脉钙化检测敏感度显著高于胸部X线(52.3% vs 超低剂量CT,P<0.001)。
要点
- 超低剂量CT(0.13±0.01 mSv)检测主动脉瓣、升主动脉和主动脉弓钙化的敏感度分别为93.5%、96.2%和96.2%。
- 胸部X线检测胸主动脉钙化的敏感度为52.3%,显著低于超低剂量CT(P<0.001)。
- 现代锡滤过CT可在胸部X线等效剂量下可靠评估胸主动脉钙化动脉粥样硬化负荷。
核心结论
- 现代锡滤过CT可在与胸部直接X线摄影相当的剂量水平下可靠评估胸主动脉钙化动脉粥样硬化负荷,诊断准确性高于传统胸部X线。
研究设计与样本
- 前瞻性、经IRB批准的单中心研究,纳入106例患者,按临床指征先行标准剂量胸部CT(1.7±0.7 mSv),同一次检查中再行100 kV锡滤过光谱整形超低剂量CT(0.13±0.01 mSv)以达到胸部X线等效剂量,以标准剂量CT为参考标准。
诊断标准与关键数值
- 超低剂量CT检测主动脉瓣钙化敏感度93.5%,以标准剂量CT为参考标准。
- 超低剂量CT检测升主动脉钙化敏感度96.2%,以标准剂量CT为参考标准。
- 超低剂量CT检测主动脉弓钙化敏感度96.2%,以标准剂量CT为参考标准。
- 胸部X线检测胸主动脉钙化敏感度52.3%,显著低于超低剂量CT(P<0.001)。
临床应用与阅片要点
- 两名独立放射科医师阅片,评估图像质量及主动脉瓣、升主动脉和主动脉弓钙化的存在与范围。
- 传统胸部X线亦被阅片评估主动脉钙化存在情况,作为对比方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the value of ultralow-dose chest CT for estimating the calcified atherosclerotic burden of the thoracic aorta using tin-filter CT and compare its diagnostic accuracy with chest direct radiography.
METHODS: A total of 106 patients from a prospective, IRB-approved single-centre study were included and underwent standard dose chest CT (1.7 ± 0.7 mSv) by clinical indication followed by ultralow-dose CT with 100 kV and spectral shaping by a tin filter (0.13 ± 0.01 mSv) to achieve chest X-ray equivalent dose in the same session. Two independent radiologists reviewed the CT images, rated image quality and estimated presence and extent of calcification of aortic valve, ascending aorta and aortic arch. Conventional radiographs were also reviewed for presence of aortic calcifications.
RESULTS: The sensitivity of ultralow-dose CT for the detection of calcifications of the aortic valve, ascending aorta and aortic arch was 93.5, 96.2 and 96.2%, respectively, compared with standard dose CT. The sensitivity for the detection of thoracic aortic calcification was significantly lower on chest X-ray (52.3%) compared with ultralow-dose CT (p < 0.001).
CONCLUSION: A reliable estimation of calcified atherosclerotic burden of the thoracic aorta can be achieved with modern tin-filter CT at dose values comparable to chest direct radiography. Advances in knowledge: Our findings suggest that ultralow-dose CT is an excellent tool for assessing the calcified atherosclerotic burden of the thoracic aorta with higher diagnostic accuracy than conventional chest radiography and importantly without the additional cost of increased radiation dose.