文献速递胸部MR

自由呼吸动态19F气体磁共振成像用于慢性阻塞性肺疾病患者区域肺通气绘测

Free-breathing Dynamic 19F Gas MR Imaging for Mapping of Regional Lung Ventilation in Patients with COPD.
PubMed 文献 · Radiology · 2017-10-03

这项经机构审查委员会批准的前瞻性研究纳入27例慢性阻塞性肺疾病患者,采用自由呼吸动态19F气体洗出磁共振成像定量区域肺通气,并与肺功能检查参数进行相关性分析。结果显示19F洗出参数与FEV1占预计值百分比显著相关,自由呼吸动态19F气体磁共振成像在1.5 T下可行。

要点

  • 19F气体洗出磁共振成像可在自由呼吸下定量区域肺通气,1.5 T下对阻塞肺段亦可行。
  • VDP从早期49%降至晚期6%,提示洗出过程可反映通气改善。
  • 中位呼吸次数、洗出时间与FEV1占预计值百分比呈负相关,FV呈正相关。

核心结论

  • 自由呼吸动态19F气体洗出磁共振成像定量区域肺通气在1.5 T下可行,即使在阻塞肺段亦可行。

研究设计与样本

  • 机构审查委员会批准的前瞻性研究,纳入27例慢性阻塞性肺疾病患者,采用屏气19F气体洗入磁共振成像(吸入常氧氟化气体混合物全氟丙烷)和自由呼吸动态19F气体洗出磁共振成像(吸入气体混合物总量25-30 L后),以肺功能检查参数为参照。

关键影像表现/征象

  • 比较初始期与晚期,所有受试者中位VDP从49%(第25-75百分位,35%-62%)降至6%(第25-75百分位,2%-10%;P < .0001)。
  • 通气区域中位FV为11.1%(第25-75百分位,6.8%-14.5%),高于VDPinitial识别的缺陷区域5.8%(第25-75百分位,4.0%-7.4%;P < .0001)。

诊断标准与关键数值

  • 中位呼吸次数与FEV1占预计值百分比呈负相关(r = -0.82;P < .0001)。
  • 中位洗出时间与FEV1占预计值百分比呈负相关(r = -0.77;P < .0001)。
  • 中位FV与FEV1占预计值百分比呈正相关(r = 0.86;P < .0001)。
  • 洗入期开始时VDP(VDPinitial)与FEV1占预计值百分比相关(r = -0.74;P = .0028),与FV相关(r = 0.74;P = .0002)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To quantify regional lung ventilation in patients with chronic obstructive pulmonary disease (COPD) by using free-breathing dynamic fluorinated (fluorine 19 [19F]) gas magnetic resonance (MR) imaging. Materials and Methods In this institutional review board-approved prospective study, 27 patients with COPD were examined by using breath-hold 19F gas wash-in MR imaging during inhalation of a normoxic fluorinated gas mixture (perfluoropropane) and by using free-breathing dynamic 19F gas washout MR imaging after inhalation of the gas mixture was finished for a total of 25-30 L. Regional lung ventilation was quantified by using volume defect percentage (VDP), washout time, number of breaths, and fractional ventilation (FV). To compare different lung function parameters, Pearson correlation coefficient and Fisher z transformation were used, which were corrected for multiple comparisons with the Bonferroni method. Results Statistically significant correlations were observed for all evaluated lung function test parameters compared with median and interquartile range of 19F washout parameters. An inverse linear correlation of median number of breaths (r = -0.82; P < .0001) and median washout times (r = -0.77; P < .0001) with percentage predicted of forced expiratory volume in 1 second (FEV1) was observed; correspondingly median FV (r = 0.86; P < .0001) correlated positively with percentage predicted FEV1. Comparing initial with late phase, median VDP of all subjects decreased from 49% (25th-75th percentile, 35%-62%) to 6% (25th-75th percentile, 2%-10%; P < .0001). VDP at the beginning of the gas wash-in phase (VDPinitial) significantly correlated with percentage predicted FEV1 (r = -0.74; P = .0028) and FV (r = 0.74; P = .0002). Median FV was significantly increased in ventilated regions (11.1% [25th-75th percentile, 6.8%-14.5%]) compared with the defect regions identified by VDPinitial (5.8% [25th-75th percentile, 4.0%-7.4%]; P < .0001). Conclusion Quantification of regional lung ventilation by using dynamic 19F gas washout MR imaging in free breathing is feasible at 1.5 T even in obstructed lung segments. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Gutberlet M, Kaireit TF, Voskrebenzev A, et al. Free-breathing Dynamic 19F Gas MR Imaging for Mapping of Regional Lung Ventilation in Patients with COPD. Radiology. 2017. PMID: 28972817. doi:10.1148/radiol.2017170591

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。