文献速递胸部CT

使用开源软件量化肿瘤异质性对磨玻璃结节进行计算机辅助诊断

Computer-Aided Diagnosis of Ground-Glass Opacity Nodules Using Open-Source Software for Quantifying Tumor Heterogeneity.
PubMed 文献 · AJR Am J Roentgenol · 2017-10-18

本研究利用高分辨率CT提取的定量影像生物标志物,将248个磨玻璃结节分为AAH、AIS、MIA和IAC四类,并训练支持向量机(SVM)预测结节类型。SVM在四分类、AIS与MIA区分及惰性 vs 侵袭性病变区分上的准确率均高于三位专家放射科医生,而对比增强未显著改善鉴别诊断。

要点

  • SVM对磨玻璃结节四分类准确率为70.9%,显著高于放射科医生的39.6%。
  • SVM区分AIS与MIA的准确率为73.1%,放射科医生为35.7%。
  • 对比增强未显著改善磨玻璃结节的鉴别诊断。

核心结论

  • 与三位放射科医生的磨玻璃结节分类相比,基于所有异质性指标训练的SVM在四分类、区分AIS与MIA以及区分惰性 vs 侵袭性病变方面表现出显著更高的准确率;对比增强未改善磨玻璃结节的鉴别诊断。

研究设计与样本

  • 研究使用定制软件量化248个磨玻璃结节的异质性;采用单变量Kruskal-Wallis检验评估四种结节组间指标的显著差异;使用异质性指标训练SVM学习并预测病变类型;SVM预测与三位专家放射科医生的分类准确率进行比较。

诊断标准与关键数值

  • 在平扫和增强CT上,分别有57个异质性指标中的50个和51个在四种磨玻璃结节组间显示出统计学显著差异。
  • SVM将磨玻璃结节分为四组的准确率为70.9%,放射科医生的准确率为39.6%。
  • SVM分类AIS和MIA结节的准确率为73.1%,放射科医生的准确率为35.7%。
  • 对于惰性 vs 侵袭性病变,SVM的准确率为88.1%,放射科医生的准确率为60.8%。

局限性

  • 对比增强未显著改善磨玻璃结节的鉴别诊断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purposes of this study are to develop quantitative imaging biomarkers obtained from high-resolution CTs for classifying ground-glass nodules (GGNs) into atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and invasive adenocarcinoma (IAC); to evaluate the utility of contrast enhancement for differential diagnosis; and to develop and validate a support vector machine (SVM) to predict the GGN type.

MATERIALS AND METHODS: The heterogeneity of 248 GGNs was quantified using custom software. Statistical analysis with a univariate Kruskal-Wallis test was performed to evaluate metrics for significant differences among the four GGN groups. The heterogeneity metrics were used to train a SVM to learn and predict the lesion type.

RESULTS: Fifty of 57 and 51 of 57 heterogeneity metrics showed statistically significant differences among the four GGN groups on unenhanced and contrast-enhanced CT scans, respectively. The SVM predicted lesion type with greater accuracy than did three expert radiologists. The accuracy of classifying the GGNs into the four groups on the basis of the SVM algorithm was 70.9%, whereas the accuracy of the radiologists was 39.6%. The accuracy of SVM in classifying the AIS and MIA nodules was 73.1%, and the accuracy of the radiologists was 35.7%. For indolent versus invasive lesions, the accuracy of the SVM was 88.1%, and the accuracy of the radiologists was 60.8%. We found that contrast enhancement does not significantly improve the differential diagnosis of GGNs.

CONCLUSION: Compared with the GGN classification done by the three radiologists, the SVM trained regarding all the heterogeneity metrics showed significantly higher accuracy in classifying the lesions into the four groups, differentiating between AIS and MIA and between indolent and invasive lesions. Contrast enhancement did not improve the differential diagnosis of GGNs.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Li M, Narayan V, Gill RR, et al. Computer-Aided Diagnosis of Ground-Glass Opacity Nodules Using Open-Source Software for Quantifying Tumor Heterogeneity. AJR Am J Roentgenol. 2017. PMID: 29045176. doi:10.2214/AJR.17.17857

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。