本研究在多中心对41例接受肺静脉隔离的患者术中进行经颅多普勒微栓子信号监测,共记录68729个微栓子信号和42次血栓栓塞雨,发现微栓子信号/血栓栓塞雨计数与新发DWI病灶、神经心理能力或长期临床事件均无相关性,提示该计数作为术中生物标志物的有效性可能受到挑战。

要点

  • 肺静脉隔离术中经颅多普勒可记录大量微栓子信号,平均每例1676个信号。
  • 微栓子信号/血栓栓塞雨计数与新发DWI病灶或神经心理能力改变无相关性。
  • 平均随访49±4个月,仅1例发生明显短暂缺血事件,且与高微栓子信号计数无关。

核心结论

  • 本多中心研究发现,肺静脉隔离术中微栓子信号/血栓栓塞雨计数与新发DWI病灶、神经心理能力或明显神经功能缺损均无相关性,该计数作为肺静脉隔离术中有效生物标志物可能受到挑战。

研究设计与样本

  • 多中心研究,共41例患者接受肺静脉隔离,术中记录微栓子信号负荷(分为「固体」「气体」「不确定」三类)及持续超过30秒的血栓栓塞雨,术前术后行DWI-MRI和神经心理测试,并通过电话进行长期随访评估卒中/短暂性脑缺血发作。

关键影像表现/征象

  • 共记录68729个微栓子信号,其中固体14893个、气体11909个、不确定41927个,平均每例1676个信号。
  • 共记录42次血栓栓塞雨。
  • 微栓子信号/血栓栓塞雨计数与新发DWI病灶或神经心理能力之间未发现相关性。
  • 平均随访49±4个月,1例患者发生明显短暂缺血事件,该事件与高微栓子信号计数无关。

诊断标准与关键数值

  • 微栓子信号经颅多普勒超声检测,分类为「固体」「气体」「不确定」三类。
  • 持续超过30秒的血栓栓塞雨被记录。
  • 新发沉默性脑栓塞通过DWI-MRI评估。
  • 神经心理后遗症通过神经心理测试评估。

临床应用与阅片要点

  • 术中经颅多普勒记录的微栓子信号计数可能不能单独作为肺静脉隔离术中临床损伤的有效生物标志物。
  • 作者认为,不仅微栓子信号计数,操作/个体因素也可能导致相应的临床损伤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Microembolic signal detection by transcranial Doppler ultrasonography may be considered a surrogate for cerebral events during invasive cardiac procedures. However, the impact of the microembolic signal count during pulmonary vein isolation on the clinical outcome is not well evaluated. We investigated the effect of the microembolic signal count on the occurrence of new silent cerebral embolism measured by diffusion-weighted imaging (DWI)-magnetic resonance imaging (MRI), changes in neuropsychological testing, and the occurrence of clinical events during long-term follow-up after pulmonary vein isolation.

METHODS: Pulmonary vein isolation was performed in 41 patients. The total microembolic signal burden (classified into "solid," "gaseous," and "equivocal") and sustained thromboembolic showers of greater than 30 seconds were recorded. Diffusion-weighted imaging-MRI and neuropsychological testing were performed before and after pulmonary vein isolation to assess for silent cerebral embolism and neuropsychological sequelae. Long-term follow-up was performed by telephone to assess for stroke/transient ischemic attack.

RESULTS: A total of 68,729 microembolic signals (14,893 solid, 11,909 gaseous, and 41,927 equivocal) with an average of 1676 signals per patient and 42 thromboembolic showers were recorded. No correlation between the microembolic signal/thromboembolic shower count and the occurrence of new DWI lesions or neuropsychological capability was found. After a mean follow-up ± SD of 49 ± 4 months, 1 patient had an overt transient ischemic event, which was not associated with a high microembolic signal count.

CONCLUSIONS: In this multicenter study, we found no impact of the intraprocedural microembolic symbol/thromboembolic shower count on the occurrence of new DWI lesions, neuropsychological capability, or overt neurologic deficits after pulmonary vein isolation. Thus, not only the microembolic signal count but also procedural/individual factors may contribute to commensurable clinical damage, which may challenge this method as a valid biomarker during pulmonary vein isolation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. von Bary C, Deneke T, Arentz T, et al. Clinical Impact of the Microembolic Signal Burden During Catheter Ablation for Atrial Fibrillation: Just a Lot of Noise? J Ultrasound Med. 2017. PMID: 29034496. doi:10.1002/jum.14447

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。