文献速递神经外周血管CTDSA

急性卒中背景下CT血管成像对颈部颈内动脉闭塞与假性闭塞的鉴别:一项准确性、观察者间及观察者内一致性研究

Cervical Internal Carotid Occlusion versus Pseudo-occlusion at CT Angiography in the Context of Acute Stroke: An Accuracy, Interobserver, and Intraobserver Agreement Study.
PubMed 文献 · Radiology · 2017-10-25

本研究回顾性纳入37例接受取栓且术前CT血管成像显示症状侧颈部颈内动脉无对比剂充盈的急性卒中患者,由7名读片者独立判读是否存在真性颈部颈内动脉闭塞,以数字减影血管造影为参考标准。结果显示假性闭塞占32.4%,平均敏感度68%、特异度75%,观察者间一致性仅为一般(κ=0.32),提示即使专业放射科医生也难以可靠鉴别真性闭塞与假性闭塞。

要点

  • 症状侧颈部颈内动脉无对比剂充盈时,假性闭塞占32.4%(12/37)。
  • CT血管成像鉴别真性闭塞的平均敏感度68%、特异度75%,诊断比值比8。
  • 观察者间一致性仅一般(κ=0.32),未达到0.61的实质性一致水平。

核心结论

  • 在急性缺血性卒中且单期CT血管成像显示同侧颈部颈内动脉无对比剂充盈的情况下,即使专业放射科医生也可能无法可靠区分真性颈部颈内动脉闭塞与假性闭塞。

研究设计与样本

  • 回顾性研究,纳入37例(24名男性、13名女性;平均年龄63岁,年龄范围30-86岁)接受取栓且术前CT血管成像显示症状侧颈部颈内动脉无对比剂充盈的患者。
  • 由7名读片者(5名神经放射科医生和2名介入神经放射学研究员)独立判读CT血管成像是否存在真性颈部颈内动脉闭塞,以数字减影血管造影为参考标准。

关键影像表现/征象

  • 症状侧颈部颈内动脉无对比剂充盈的患者中,12/37例(32.4%)为假性闭塞(定义为孤立的颅内血栓阻碍上行血流)。

诊断标准与关键数值

  • CT血管成像检测真性颈部颈内动脉闭塞的平均敏感度为68%(95%CI:59%,76%),平均特异度为75%(95%CI:71%,80%)。
  • 诊断比值比为8(95%CI:3,18),观察者间一致性κ=0.32(95%CI:0.16,0.47),仅为一般一致性。
  • 观察者间一致性系数在读者对或读者组均未达到0.61的实质性一致水平。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the diagnostic accuracy and reliability of computed tomographic (CT) angiography to distinguish true cervical internal carotid artery (ICA) occlusion from pseudo-occlusion (defined as an isolated intracranial thrombus that impedes ascending blood flow) in the context of acute stroke. Materials and Methods This was a retrospective study of patients who underwent thrombectomy with preprocedural CT angiography that helps to demonstrate a lack of attenuation in the cervical ICA on the symptomatic side (24 men and 13 women; mean age, 63 years; age range, 30-86 years). Seven readers, including five neuroradiologists and two interventional neuroradiology fellows, independently reviewed the CT angiography images to assess whether there was true cervical ICA occlusion. Their results were compared with digital subtraction angiography (DSA) as the reference standard. Sensitivity and specificity for detecting true occlusion as well as accuracy and diagnostic odds ratio were calculated, with inter- and intraobserver κ statistics. Results Cervical ICA pseudo-occlusion occurred in 12 of 37 patients (32.4%) with nonattenuation of the cervical ICA on the symptomatic side. Interobserver agreement coefficients did not reach the substantial value of 0.61 for either pairs or groups of readers. The cohort's average sensitivity and specificity was 68% (95% confidence interval [CI]: 59%, 76%) and 75% (95% CI: 71%, 80%), respectively, with a diagnostic odds ratio of 8 (95% CI: 3, 18) and only fair interobserver agreement (κ = 0.32; 95% CI: 0.16, 0.47). Conclusion In the context of acute ischemic stroke with ipsilateral ICA nonattenuation at single-phase CT angiography, even specialized radiologists may not reliably distinguish true cervical occlusion from pseudo-occlusion. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Diouf A, Fahed R, Gaha M, et al. Cervical Internal Carotid Occlusion versus Pseudo-occlusion at CT Angiography in the Context of Acute Stroke: An Accuracy, Interobserver, and Intraobserver Agreement Study. Radiology. 2017. PMID: 29072979. doi:10.1148/radiol.2017170681

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。