比较头颈部双层探测器CT血管造影重建的虚拟单能图像与多能图像
回顾性纳入30例头颈部双层探测器CT血管造影患者,重建多能图像及40至120 keV虚拟单能图像,测量颈部和脑部血管信号并计算CNR和SNR,同时用5分Likert量表评估主观图像质量。与多能图像相比,40 keV和45 keV虚拟单能图像在颈部、岩部及颅内血管的CNR和SNR改善,且血管对比度、颅底附近动脉及小动脉分支的评估更优。
要点
- 40至45 keV虚拟单能图像可改善颅内外血管的客观和主观图像质量。
- 低 keV 下噪声增加,但40 keV虚拟单能图像的CNR仍优于多能图像。
- 45 keV虚拟单能图像在血管对比度、颅底附近动脉及小动脉分支评估上更优。
核心结论
- 与多能图像相比,双层探测器CT血管造影重建的40至45 keV低 keV 虚拟单能图像改善颅内外血管的客观和主观图像质量,并有助于评估颅底附近血管和小动脉分支。
研究设计与样本
- 回顾性识别30例接受头颈部双层探测器CT血管造影的患者,重建多能图像及40至120 keV虚拟单能图像,测量颈部和脑部血管及翼外肌和头部周围空气的信号以计算CNR和SNR,并用5分Likert量表评估主观图像质量,采用Student t检验和Wilcoxon检验确定统计学显著性。
关键影像表现/征象
- 与多能图像相比,40 keV虚拟单能图像的颈部、岩部和颅内血管CNR改善(p < 0.02),SNR改善(p > 0.05)。
- 45 keV虚拟单能图像在血管对比度、颅底附近动脉评估和小动脉分支评估方面评分更优(每项p < 0.0001)。
- 低 keV 下噪声增加。
诊断标准与关键数值
- 40 keV虚拟单能图像相比多能图像:颈部、岩部和颅内血管CNR改善(p < 0.02),SNR改善(p > 0.05)。
- 45 keV虚拟单能图像相比多能图像:血管对比度、颅底附近动脉评估和小动脉分支评估的主观评分更优(p < 0.0001)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the image quality of virtual monoenergetic images and polyenergetic images reconstructed from dual-layer detector CT angiography (DLCTA).
METHODS: Thirty patients who underwent DLCTA of the head and neck were retrospectively identified and polyenergetic as well as virtual monoenergetic images (40 to 120 keV) were reconstructed. Signals (± SD) of the cervical and cerebral vessels as well as lateral pterygoid muscle and the air surrounding the head were measured to calculate the CNR and SNR. In addition, subjective image quality was assessed using a 5-point Likert scale. Student's t-test and Wilcoxon test were used to determine statistical significance.
RESULTS: Compared to polyenergetic images, although noise increased with lower keV, CNR (p < 0.02) and SNR (p > 0.05) of the cervical, petrous and intracranial vessels were improved in virtual monoenergetic images at 40 keV and virtual monoenergetic images at 45 keV were also rated superior regarding vascular contrast, assessment of arteries close to the skull base and small arterial branches (p < 0.0001 each).
CONCLUSIONS: Compared to polyenergetic images, virtual monoenergetic images reconstructed from DLCTA at low keV ranging from 40 to 45 keV improve the objective and subjective image quality of extra- and intracranial vessels and facilitate assessment of vessels close to the skull base and of small arterial branches.
KEY POINTS: • Virtual monoenergetic images greatly improve attenuation, while noise only slightly increases. • Virtual monoenergetic images show superior contrast-to-noise ratios compared to polyenergetic images. • Virtual monoenergetic images significantly improve image quality at low keV.