文献速递神经技术与安全US

对比增强超声作为脑灌注床旁监测技术的潜力:系统综述

Potential of Contrast-Enhanced Ultrasound as a Bedside Monitoring Technique in Cerebral Perfusion: a Systematic Review.
PubMed 文献 · Ultrasound Med Biol · 2017-09-28

该系统综述纳入1994年1月至2017年3月间使用对比增强超声(CEUS)测量脑灌注的43项研究、共861例患者,评估不同CEUS技术的耐受性、重复性、可重复性和准确性。耐受性方面28项研究描述了12例轻度短暂副作用;重复性在经验丰富的超声医师中较高,经验较少者显著较低;可重复性不明确;CEUS检测脑缺血的敏感度为75%至96%,特异度为60%至100%。

要点

  • CEUS检测脑缺血的敏感度为75%至96%,特异度为60%至100%。
  • 耐受性方面,28项研究描述了12例轻度短暂副作用。
  • 重复性在经验丰富的超声医师中较高,经验较少者显著较低。

核心结论

  • 关于重复性、可重复性和准确性的有限数据可能提示该技术对急性脑损伤患者可行。

研究设计与样本

  • 系统综述纳入1994年1月至2017年3月发表的43项研究,包括团注动力学31项、再填充动力学6项、耗竭动力学6项,共861例患者。

诊断标准与关键数值

  • CEUS检测脑缺血的敏感度范围为75%至96%,特异度范围为60%至100%。
  • 重复性在3项研究中评估,可重复性在2项研究中评估,准确性在19项研究中评估。
  • 重复性在经验丰富的超声医师中较高,在经验较少的超声医师中显著较低。
  • CEUS的可重复性不明确。

局限性

  • 关于重复性、可重复性和准确性的数据有限。
  • CEUS的可重复性不明确。
  • 有限数据可能提示该技术对急性脑损伤患者可行。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Contrast-enhanced ultrasound (CEUS) has been suggested as a new method to measure cerebral perfusion in patients with acute brain injury. In this systematic review, the tolerability, repeatability, reproducibility and accuracy of different CEUS techniques for the quantification of cerebral perfusion were assessed. We selected studies published between January 1994 and March 2017 using CEUS to measure cerebral perfusion. We included 43 studies (bolus kinetics n = 31, refill kinetics n = 6, depletion kinetics n = 6) with a total of 861 patients. Tolerability was reported in 28 studies describing 12 patients with mild and transient side effects. Repeatability was assessed in 3 studies, reproducibility in 2 studies and accuracy in 19 studies. Repeatability was high for experienced sonographers and significantly lower for less experienced sonographers. Reproducibility of CEUS was not clear. The sensitivity and specificity of CEUS for the detection of cerebral ischemia ranged from 75% to 96% and from 60% to 100%. Limited data on repeatability, reproducibility and accuracy may suggest that this technique could be feasible for use in acute brain injury patients.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Vinke EJ, Kortenbout AJ, Eyding J, et al. Potential of Contrast-Enhanced Ultrasound as a Bedside Monitoring Technique in Cerebral Perfusion: a Systematic Review. Ultrasound Med Biol. 2017. PMID: 28964614. doi:10.1016/j.ultrasmedbio.2017.08.935

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。