文献速递神经MR

灌注治疗前FLAIR血管高信号是否代表良好的侧支循环

Do Fluid-Attenuated Inversion Recovery Vascular Hyperintensities Represent Good Collaterals before Reperfusion Therapy?
PubMed 文献 · AJNR Am J Neuroradiol · 2017-10-26

研究纳入244例适合再灌注治疗的MCA卒中患者,治疗前完成FLAIR与PWI检查,以灌注不足强度比≤0.35定义良好侧支。结果显示FLAIR血管高信号范围在良好侧支组更广泛,且FLAIR血管高信号评分与良好侧支独立相关(趋势P=0.002)。

要点

  • FLAIR血管高信号范围越广,提示侧支循环越好,可用于快速筛选再灌注治疗获益人群。
  • 灌注不足强度比≤0.35定义为良好侧支,>0.35为不良侧支。
  • FLAIR血管高信号评分基于ASPECTS,范围0–7分,评分越高提示侧支越好。

核心结论

  • 在适合再灌注治疗的患者中,FLAIR血管高信号范围与治疗前灌注不足强度比评估的良好侧支相关,基于ASPECTS的FLAIR血管高信号评估可用于快速识别更可能从再灌注治疗中获益的患者。

研究设计与样本

  • 连续纳入244例适合再灌注治疗的大脑中动脉卒中患者,治疗前完成MR FLAIR与PWI检查,以灌注不足强度比中位数0.35将侧支分为良好(≤0.35)与不良(>0.35)。

关键影像表现/征象

  • 所有患者均存在灌注不足,中位灌注不足强度比为0.35(四分位距0.19–0.48)。
  • FLAIR血管高信号评分中位数为4分(四分位距3–5分)。
  • 良好侧支(灌注不足强度比≤0.35)患者的FLAIR血管高信号范围较不良侧支(>0.35)更广泛(趋势P=0.016)。
  • FLAIR血管高信号评分与良好侧支独立相关(趋势P=0.002)。

诊断标准与关键数值

  • FLAIR血管高信号评分基于ASPECTS,0分表示无FLAIR血管高信号,7分表示FLAIR血管高信号紧邻所有ASPECTS皮层区域。
  • 灌注不足强度比定义为时间-最大值>10秒与>6秒的病灶体积比值。
  • 以灌注不足强度比中位数0.35为界,≤0.35定义为良好侧支,>0.35定义为不良侧支。

临床应用与阅片要点

  • 作者认为,基于ASPECTS的FLAIR血管高信号评估可用于快速识别更可能从再灌注治疗中获益的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: In acute ischemic stroke, whether FLAIR vascular hyperintensities represent good or poor collaterals remains controversial. We hypothesized that extensive FLAIR vascular hyperintensities correspond to good collaterals, as indirectly assessed by the hypoperfusion intensity ratio.

MATERIALS AND METHODS: We included 244 consecutive patients eligible for reperfusion therapy with MCA stroke and pretreatment MR imaging with both FLAIR and PWI. The FLAIR vascular hyperintensity score was based on ASPECTS, ranging from 0 (no FLAIR vascular hyperintensity) to 7 (FLAIR vascular hyperintensities abutting all ASPECTS cortical areas). The hypoperfusion intensity ratio was defined as the ratio of the time-to-maximum >10-second over time-to-maximum >6-second lesion volumes. The median hypoperfusion intensity ratio was used to dichotomize good (low hypoperfusion intensity ratio) versus poor (high hypoperfusion intensity ratio) collaterals. We then studied the association between FLAIR vascular hyperintensity extent and hypoperfusion intensity ratio.

RESULTS: Hypoperfusion was present in all patients, with a median hypoperfusion intensity ratio of 0.35 (interquartile range, 0.19-0.48). The median FLAIR vascular hyperintensity score was 4 (interquartile range, 3-5). The FLAIR vascular hyperintensities were more extensive in patients with good collaterals (hypoperfusion intensity ratio ≤0.35) than with poor collaterals (hypoperfusion intensity ratio >0.35; P for Trend = .016). The FLAIR vascular hyperintensity score was independently associated with good collaterals (P for Trend = .002).

CONCLUSIONS: In patients eligible for reperfusion therapy, FLAIR vascular hyperintensity extent was associated with good collaterals, as assessed by the pretreatment hypoperfusion intensity ratio. The ASPECTS assessment of FLAIR vascular hyperintensities could be used to rapidly identify patients more likely to benefit from reperfusion therapy.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Mahdjoub E, Turc G, Legrand L, et al. Do Fluid-Attenuated Inversion Recovery Vascular Hyperintensities Represent Good Collaterals before Reperfusion Therapy? AJNR Am J Neuroradiol. 2017. PMID: 29074634. doi:10.3174/ajnr.A5431

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。