文献速递介入腹部DSA

钝性创伤中的脾动脉栓塞:明胶海绵与弹簧圈应用的单中心回顾性比较

Splenic Artery Embolization in Blunt Trauma: A Single-Center Retrospective Comparison of the Use of Gelatin Sponge Versus Coils.
PubMed 文献 · AJR Am J Roentgenol · 2017-09-20

单中心回顾性比较63例钝性脾损伤患者,分别用明胶海绵(30例)或金属弹簧圈(33例)行脾动脉栓塞;两组栓塞失败率、主要及次要并发症无显著差异,明胶海绵组手术时间显著更短(中位32分钟 vs 53分钟,p=0.01)。

要点

  • 明胶海绵组与弹簧圈组脾动脉栓塞失败率分别为6.6%(2/30)和12.1%(4/33),差异无统计学意义(p=0.45)。
  • 明胶海绵组手术时间中位32分钟(四分位距18-48分钟)显著短于弹簧圈组53分钟(30-76分钟)(p=0.01)。
  • 两组主要并发症发生率分别为20.0%(6/30)和18.1%(6/33),差异无统计学意义(p=0.85)。

核心结论

  • 明胶海绵行脾动脉栓塞在疗效和安全性上似乎与弹簧圈相当,且手术时间更短。

研究设计与样本

  • 单中心回顾性研究,纳入2005年至2014年间63例钝性脾损伤患者(45男18女,平均年龄45.5岁,范围16-84岁),明胶海绵组30例、金属弹簧圈组33例;两组栓塞前脾动脉造影活动性外溢和假性动脉瘤表现具有可比性(p=0.32),美国创伤外科协会分级中位数均为IV级。

诊断标准与关键数值

  • 脾动脉栓塞失败率:明胶海绵组6.6%(2/30),弹簧圈组12.1%(4/33)(p=0.45;95%CI -30.1%至19.2%)。
  • 主要并发症发生率:明胶海绵组20.0%(6/30),弹簧圈组18.1%(6/33)(p=0.85;95%CI -23.0%至26.6%)。
  • 次要并发症发生率:明胶海绵组10.0%(3/30),弹簧圈组21.2%(7/33)(p=0.21;95%CI -35.4%至14.0%)。
  • 手术时间中位数:明胶海绵组32分钟(四分位距18-48分钟) vs 弹簧圈组53分钟(30-76分钟)(p=0.01)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to compare the efficacy of gelatin sponge with that of coils for splenic artery embolization in the treatment of blunt splenic injury.

MATERIALS AND METHODS: A single-center retrospective review was performed with the records of 63 patients (45 men, 18 women; mean age, 45.5 years; range, 16-84 years) with blunt splenic injury treated at a tertiary care trauma center by splenic artery embolization with gelatin sponge (n = 30 patients) or metallic coils (n = 33 patients) between 2005 and 2014. The two groups had comparable median American Association for the Surgery of Trauma grades of IV and comparable angiographic appearances regarding active extravasation and pseudoaneurysm formation at preembolization splenic arteriography (p = 0.32). Clinical outcomes and procedure-related outcomes were evaluated.

RESULTS: The success rates were similar in the two groups: splenic artery embolization failed in 6.6% (2/30) of patients in the gelatin sponge group and 12.1% (4/33) in the coil embolization group (p = 0.45; 95% CI, -30.1% to 19.2%). Major complications occurred in six patients (20.0%) in the gelatin sponge group and in six patients (18.1%) in the coil group (p = 0.85; 95% CI, -23.0% to 26.6%). Minor complications occurred in three patients (10.0%) in the gelatin sponge group and seven patients (21.2%) in the coil group (p = 0.21; 95% CI, -35.4% to 14.0%). Procedure time was significantly shorter in the gelatin sponge group (median, 32 minutes; interquartile range, 18-48 minutes) than in the coil group (median, 53 minutes; interquartile range, 30-76 minutes) (p = 0.01).

CONCLUSION: Splenic artery embolization with gelatin sponge appears to be as effective and as safe as coil embolization and can be completed in a shorter time.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Rasuli P, Moosavi B, French GJ, et al. Splenic Artery Embolization in Blunt Trauma: A Single-Center Retrospective Comparison of the Use of Gelatin Sponge Versus Coils. AJR Am J Roentgenol. 2017. PMID: 28929807. doi:10.2214/AJR.17.18005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。