智能手机引导的CT引导穿刺术中针角选择
研究开发了一款iPhone应用,基于手机方向实时将计划进针角度叠加于摄像头画面,通过体模实验评估硬件精度(0.37°±0.27°)、Guideline模式(资深放射科医师误差1.0°±0.9°、导航时间8.7±2.3秒;初级医师1.5°±1.3°、8.0±1.6秒)和Bull's-Eye View模式(精度2.9°±1.1°),并完成一例概念验证临床病例。CT联合智能手机引导首次进针精度显著优于单纯CT引导(p=0.046),最终靶向误差更小(针尖至目标平均距离2.5 vs 7.9 mm)。结论认为移动设备可用于引导针基介入,硬件成本低且易获取,方法准确、有效、易实施。
要点
- 智能手机应用可实时叠加计划进针角度,辅助术者选择穿刺针角度。
- 体模实验中硬件精度为0.37°±0.27°,Bull's-Eye View模式精度为2.9°±1.1°。
- CT联合智能手机引导首次进针精度显著优于单纯CT引导(p=0.046),最终靶向误差更小(2.5 vs 7.9 mm)。
核心结论
- 移动设备可用于引导针基介入,硬件成本低且广泛可用,该方法准确、有效且易于实施。
研究设计与样本
- 体模研究评估硬件、Guideline模式和Bull's-Eye View模式的精度,并完成一例概念验证临床病例;未报告样本量、中心数及参考标准。
诊断标准与关键数值
- 硬件精度为0.37°±0.27°(均值±标准差)。
- 资深放射科医师(25年经验)平均误差1.0°±0.9°、导航时间8.7±2.3秒。
- 初级放射科医师(4年经验)平均误差1.5°±1.3°、导航时间8.0±1.6秒。
- Bull's-Eye View模式精度为2.9°±1.1°。
- CT联合智能手机引导首次进针精度显著优于单纯CT引导(p=0.046),最终靶向误差更小(针尖至目标平均距离2.5 vs 7.9 mm)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles.
MATERIALS AND METHODS: The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed.
RESULTS: The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm).
CONCLUSION: Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.
引用
- Xu S, Krishnasamy V, Levy E, et al. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures. AJR Am J Roentgenol. 2017. PMID: 28952812. doi:10.2214/AJR.17.18498
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。