文献速递骨肌MR

快速5分钟膝关节MRI方案与标准膝关节MRI方案的比较:一项多机构多阅片者研究

Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol: a multi-institutional multi-reader study.
PubMed 文献 · Skeletal Radiol · 2017-09-26

该研究回顾性比较了5分钟快速膝关节MRI方案与标准方案的诊断效能,由四名肌骨放射科医生在两家学术中心对100例3T和50例1.5T MRI进行阅片。快速方案与标准方案在半月板、韧带、软骨和骨病变的协议间一致性(83.0-99.5%)与标准方案协议内一致性相似,无过度不一致(≤1.2;95%CI -4.2至3.8%)。除快速MRI显示更多前交叉韧带撕裂(p=0.021)和标准MRI显示更多软骨缺损(p<0.001)外,主要发现频率无显著差异;对半月板和韧带撕裂的敏感度(59-100%)和特异度(73-99%)无显著差异。结论认为快速5分钟MRI方案与标准膝关节MRI可互换且准确性相似。

要点

  • 快速5分钟膝关节MRI方案与标准方案在半月板、韧带、软骨和骨病变评估中具有可互换性。
  • 快速方案与标准方案的协议间一致性为83.0-99.5%,与标准方案协议内一致性相似。
  • 快速MRI显示更多前交叉韧带撕裂(p=0.021),标准MRI显示更多软骨缺损(p<0.001)。

核心结论

  • 快速5分钟MRI方案与标准膝关节MRI在评估膝关节内部紊乱方面可互换且准确性相似。

研究设计与样本

  • 回顾性多机构多阅片者研究,纳入100例3T(100名患者,平均38.8岁)和50例1.5T(46名患者,平均46.4岁)MRI,来自两家学术中心(2015年1月至2016年1月),由四名肌骨放射科医生阅片;快速方案包括5个快速二维多平面快速自旋回波(FSE)序列,标准方案包括5个标准多平面FSE序列。

诊断标准与关键数值

  • 快速与标准MRI的协议间一致性为83.0-99.5%,无过度不一致(≤1.2;95%CI -4.2至3.8%)。
  • 主要发现频率在各结构为1.1-22.4%,快速与标准MRI无显著差异(p≥0.215),但快速MRI显示更多前交叉韧带撕裂(p=0.021),标准MRI显示更多软骨缺损(p<0.001)。
  • 对半月板和韧带撕裂,快速与标准MRI的敏感度(59-100%)和特异度(73-99%)无显著差异(差值95%CI -0.08至0.08)。
  • 对软骨缺损,快速MRI敏感度略低(差值95%CI -0.125至-0.01),但特异度略高(差值95%CI 0.01至0.5)。

临床应用与阅片要点

  • 快速5分钟膝关节MRI方案可用于评估膝关节内部紊乱,与标准方案可互换。
  • 阅片时注意快速MRI可能显示更多前交叉韧带撕裂,标准MRI可能显示更多软骨缺损。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI.

MATERIALS AND METHODS: One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol.

RESULTS: Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI.

CONCLUSION: A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Alaia EF, Benedick A, Obuchowski NA, et al. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol: a multi-institutional multi-reader study. Skeletal Radiol. 2017. PMID: 28952012. doi:10.1007/s00256-017-2780-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。