多普勒超声先进动态血流评估跟腱血管化的可靠性研究
本研究采用重测设计,由3名研究者对67份记录应用Ohberg评分、改良Ohberg评分和计数评分评估跟腱血管化,分析观察者内和观察者间信度。改良Ohberg评分和计数评分显示出优秀信度,而Ohberg评分观察者间信度意外偏低。
要点
- 改良Ohberg评分和计数评分信度优秀,适合研究与临床使用。
- Ohberg评分观察者内信度尚可,但观察者间信度低,不推荐使用。
- 计数评分观察者内ICC 0.94-0.97,观察者间ICC 0.91-0.98。
核心结论
- 改良Ohberg评分和计数评分信度优秀,似乎便于研究和临床实践;Ohberg评分观察者内信度尚可但观察者间信度意外偏低,因此不能推荐使用。
研究设计与样本
- 重测设计,3名研究者评估67份记录的跟腱血管化,应用Ohberg评分、改良Ohberg评分和计数评分。
诊断标准与关键数值
- Ohberg评分观察者内绝对/相对一致性为0.61-0.87/0.87-0.95,观察者间为0.11-0.66/0.76-0.89。
- 改良Ohberg评分观察者内绝对/相对一致性为0.81-0.87/0.92-0.95,观察者间为0.64-0.80/0.88-0.93。
- 计数评分观察者内ICC为0.94-0.97(SEM 1.0-1.5,偏倚-1,LoA 3-4支血管)。
- 计数评分观察者间ICC为0.91-0.98(SEM 1.0-1.9,偏倚0,LoA 3-5支血管)。
临床应用与阅片要点
- 作者认为改良Ohberg评分和计数评分信度优秀,似乎便于研究和临床实践。
- 作者认为Ohberg评分不能推荐使用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The reliability of quantifying intratendinous vascularization by high-sensitivity Doppler ultrasound advanced dynamic flow has not been examined yet. Therefore, this study aimed to investigate the intraobserver and interobserver reliability of evaluating Achilles tendon vascularization by advanced dynamic flow using established scoring systems.
METHODS: Three investigators evaluated vascularization in 67 recordings in a test-retest design, applying the Ohberg score, a modified Ohberg score, and a counting score. Intraobserver and interobserver agreement for the Ohberg score and modified Ohberg score was analyzed by the Cohen κ and Fleiss κ coefficients (absolute), Kendall τ b coefficient, and Kendall coefficient of concordance (W; relative). The reliability of the counting score was analyzed by intraclass correlation coefficients (ICC) 2.1 and 3.1, the standard error of measurement (SEM), and Bland-Altman analysis (bias and limits of agreement [LoA]).
RESULTS: Intraobserver and interobserver agreement (absolute/relative) ranged from 0.61 to 0.87/0.87 to 0.95 and 0.11 to 0.66/0.76 to 0.89 for the Ohberg score and from 0.81 to 0.87/0.92 to 0.95 and 0.64 to 0.80/0.88 to 0.93 for the modified Ohberg score, respectively. The counting score revealed an intraobserver ICC of 0.94 to 0.97 (SEM, 1.0-1.5; bias, -1; and LoA, 3-4 vessels). The interobserver ICC for the counting score ranged from 0.91 to 0.98 (SEM, 1.0-1.9; bias, 0; and LoA, 3-5 vessels).
CONCLUSIONS: The modified Ohberg score and counting score showed excellent reliability and seem convenient for research and clinical practice. The Ohberg score revealed decent intraobserver but unexpected low interobserver reliability and therefore cannot be recommended.