全长下肢与全脊柱X线摄影的辐射剂量降低
本研究纳入223例患者,比较标准剂量与低剂量全长下肢及全脊柱X线片的诊断性能。结果显示标准剂量组DAP和有效剂量均显著高于低剂量组(p<0.05),但两组主观图像质量评分及诊断性能评分均很高且无显著差异(p值0.15-0.99)。作者结论为将mAs降至标准剂量的50%不影响图像质量或临床有效性。
要点
- 低剂量组mAs为标准剂量的50%,其DAP和有效剂量均显著低于标准剂量组(p<0.05)。
- 两组全长下肢及全脊柱片的主观图像质量评分均很高,且无显著差异(p值0.15-0.99)。
- 两组诊断性能评分均很高(范围2.92-3.00),降低mAs不影响临床有效性。
核心结论
- 将mAs降至标准剂量的50%不影响全长下肢和全脊柱X线片的图像质量或临床有效性。
研究设计与样本
- 本研究纳入223例在本院接受全长下肢站立位X线摄影和全脊柱X线摄影的患者,比较标准剂量与低剂量组的DAP和基于DAP计算的有效剂量(ED,mSv),并主观评价图像质量和诊断性能。
诊断标准与关键数值
- 全长下肢片图像质量评估骨皮质和骨小梁,诊断性能通过腿长测量评估;全脊柱片图像质量评估椎体终板、椎弓根和椎体侧缘,诊断性能通过Cobb角测量评估;两组主观评分均很高,全长下肢组标准剂量2.94-2.98、低剂量组2.91-3.00,诊断性能评分范围2.92-3.00,差异无统计学意义(p值0.15-0.99)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the diagnostic performance of standard- and low-dose radiographs of the full-length lower extremity and spine.
METHODS: This study included 223 patients who visited our hospital and received full-length lower extremity standing radiographs and full-spine radiographs. We determined the dose area product (DAP) of each image, and effective doses (ED, mSv) were calculated based on the DAP. Subjective evaluation of the full-length radiographs was based on image quality, which was assessed by bony cortex and trabecula evaluation, and on diagnostic performance, which was assessed by leg length measurement. Subjective evaluation of the full-spine radiographs was based on image quality, which was assessed by viewing the vertebral endplate, pedicle and lateral border of vertebral body, and on diagnostic performance from measurement of Cobb's angle.
RESULTS: For the full-length view and the full-spine view both the mean DAP and ED values of the standard-dose group were significantly higher than those of the low-dose group (p < 0.05). Mean scores for subjective values did not significantly differ based on the radiation dosage (p-values, 0.15-0.99). The subjective value scores for the full-length view were 2.94-2.98 in the standard-dose group and 2.91-3.00 in the low-dose group. Of note, both groups had very high scores. Additionally, the diagnostic performance scores between the two groups were also very high (range from 2.92 to 3.00).
CONCLUSION: Reducing mAs by 50% of the standard dose does not affect the radiograph image quality or its clinical validity. Advances in knowledge: Radiation dose reduction (50% of the standard dose of mAs) in plain radiography of the full-length lower extremity and full spine do not affect the clinical validity and the image quality.
引用
- Jeon MR, Park HJ, Lee SY, et al. Radiation dose reduction in plain radiography of the full-length lower extremity and full spine. Br J Radiol. 2017. PMID: 28936890. doi:10.1259/bjr.20170483