基于多叶准直器的射波刀用于脊柱立体定向体部放疗的临床结局
回顾性分析2014年11月至2016年3月间接受射波刀治疗的119例患者共144个病例、229个病灶,比较固定锥形准直器射波刀(CK-F)与多叶准直器射波刀(CK-M)的剂量学参数和临床结局。CK-M靶区覆盖与CK-F相当(中位92% vs 90%;p=0.03),梯度指数改善(p<0.001),中位束流输送时间缩短30%(34 vs 48分钟;p<0.001),1年局部控制率相当(77% vs 78%;p=0.83)。
要点
- CK-M靶区覆盖与CK-F相当(中位92% vs 90%;p=0.03),即使靶区较大(中位64.2 vs 46.7 cm³;p=0.01)亦然。
- CK-M梯度指数改善(p<0.001),适形性无差异(p=0.16)。
- CK-M中位束流输送时间较CK-F缩短30%(34 vs 48分钟;p<0.001),1年局部控制率相当(77% vs 78%;p=0.83)。
核心结论
- CK-M的剂量学数据和局部控制与CK-F相当,但治疗时间显著缩短;CK-M可广泛用于脊柱SBRT。
研究设计与样本
- 回顾性研究,纳入2014年11月至2016年3月间接受射波刀治疗的119例患者共144个病例、229个病灶;144个病例中78个采用CK-F、66个采用CK-M;比较病灶特征、剂量学参数和临床结局。
诊断标准与关键数值
- CK-M靶区覆盖中位92% vs CK-F中位90%(p=0.03),靶区体积中位64.2 vs 46.7 cm³(p=0.01)。
- CK-M梯度指数改善(p<0.001),适形性无差异(p=0.16)。
- CK-M中位束流输送时间34分钟 vs CK-F 48分钟,缩短30%(p<0.001)。
- CK-M 1年局部控制率77% vs CK-F 78%(p=0.83)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Stereotactic body radiotherapy (SBRT) for spinal metastases is becoming a prevalent therapeutic option. We aimed to evaluate the clinical feasibility and outcomes of the recently developed multileaf collimator (MLC)-based CyberKnife (CK-M) for spine SBRT.
METHODS: We reviewed 119 patients of 144 cases with 229 lesions treated with CK between November 2014 and March 2016. The lesion features, dosimetric parameters and clinical outcomes were compared between fixed cone collimator based CK (CK-F) and CK-M.
RESULTS: Of 144 cases, 78 and 66 were treated with CK-F and CK-M, respectively. CK-M achieved an adequate target volume coverage that was comparable with CK-F (median 92 vs 90%; p = 0.03) even in larger targets (median 64.2 vs 46.7 cm3; p = 0.01), respectively. CK-M showed an improvement in the gradient index (p < 0.001) and no difference in conformity (p = 0.16). With CK-M, the median beam delivery time was significantly reduced by 30% (to 34 vs 48 min; p < 0.001). CK-M showed 1 year local control rates that were comparable to CK-F (77 vs 78%, respectively; p = 0.83).
CONCLUSION: CK-M exhibits dosimetric data and local control that are comparable with CK-F, but with significant treatment time reduction. CK-M could be widely used in spine SBRT. Advances in knowledge: Given the recently developed MLC in CK, we aimed to evaluate the clinical feasibility and outcomes of MLC compared with fixed cone-based CK. MLC showed equivalent plan quality and significant treatment time reduction with comparable radiological control. We report here MLC as an effective and tolerable treatment option in CK.