文献速递骨肌儿科影像技术与安全PETCTMR

儿童患者局部骨肉瘤复发的FDG PET/CT表现

FDG PET/CT appearance of local osteosarcoma recurrences in pediatric patients.
PubMed 文献 · Pediatr Radiol · 2017-09-08

回顾性分析8例儿童骨肉瘤患者共10处经病理证实的局部复发,FDG PET/CT均显示复发灶,呈实性或周边/结节状摄取,最大SUV 3.0~15.7;在5处同时有MRI的复发中3处MRI受限或无法诊断,在4处同时有骨扫描的复发中3处骨扫描阴性。

要点

  • 儿童骨肉瘤局部复发在FDG PET/CT上呈实性或周边/结节状FDG摄取,最大SUV范围3.0~15.7。
  • 金属植入物伪影可致MRI受限或无法诊断,PET/CT可显示复发全貌。
  • PET/CT检测局部骨肉瘤复发似乎比骨扫描更敏感。

核心结论

  • FDG PET/CT能清晰显示儿童骨肉瘤局部复发,表现为实性或周边/结节状FDG摄取,最大SUV范围宽,可显示复发全貌,且似乎比骨扫描更敏感。

研究设计与样本

  • 回顾性研究,纳入8例经病理证实的儿童骨肉瘤局部复发患者共10处复发,行FDG PET/CT并与可获得的对比影像(MRI、骨扫描)对照。

关键影像表现/征象

  • 所有局部复发均被FDG PET/CT显示,FDG摄取呈实性(n=5)或周边/结节状(n=5)。
  • 最大SUV范围为3.0~15.7。
  • 5处复发同时行FDG PET/CT与MRI,其中3处MRI受限或无法诊断。
  • 4处复发同时行FDG PET/CT与骨扫描,其中3处骨扫描阴性。

诊断标准与关键数值

  • 最大SUV范围为3.0~15.7。
  • FDG摄取模式分为实性(n=5)或周边/结节状(n=5)。

临床应用与阅片要点

  • 全部8例患者均为保肢术后局部复发,其中2例为截肢后再次局部复发。
  • FDG PET/CT可显示局部复发全貌,而MRI可能因金属植入物伪影受限或无法诊断。
  • PET/CT检测局部骨肉瘤复发似乎比骨扫描更敏感。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Osteosarcoma is the most common pediatric malignant bone tumor, frequently surgically managed with limb salvage rather than amputation. Local recurrences are seen in up to 9% of osteosarcoma patients, with CT and MRI imaging often limited by metal artifacts.

OBJECTIVE: To describe the [F-18]2-fluoro-2-deoxyglucose (FDG) PET/CT appearance of local osteosarcoma recurrences with correlation to findings on other imaging modalities.

MATERIALS AND METHODS: A retrospective review of pediatric osteosarcoma patients imaged with FDG PET/CT was performed in patients with pathologically proven local recurrences. FDG PET/CT findings were reviewed and correlated with available comparison imaging studies.

RESULTS: Ten local osteosarcoma recurrences in eight pediatric osteosarcoma patients were imaged with FDG PET/CT. All eight patients had a local recurrence after limb salvage; two patients had a second local recurrence after amputation. All local recurrences were seen with FDG PET/CT, demonstrating solid (n=5) or peripheral/nodular (n=5) FDG uptake patterns. Maximum standard uptake values (SUVs) ranged from 3.0 to 15.7. In five recurrences imaged with FDG PET/CT and MRI, MRI was limited or nondiagnostic in three. In four recurrences imaged with FDG PET/CT and bone scan, the bone scan was negative in three.

CONCLUSION: Local osteosarcoma recurrences are well visualized by FDG PET/CT, demonstrating either solid or peripheral/nodular FDG uptake with a wide range of maximum SUVs. FDG PET/CT demonstrates the full extent of local recurrences, while MRI can be limited by artifact from metallic hardware. PET/CT appears to be more sensitive than bone scan in detecting local osteosarcoma recurrences.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Sharp SE, Shulkin BL, Gelfand MJ, et al. FDG PET/CT appearance of local osteosarcoma recurrences in pediatric patients. Pediatr Radiol. 2017. PMID: 28887617. doi:10.1007/s00247-017-3963-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。