病灶大小是否影响剪切波弹性成像鉴别甲状腺结节良恶性的价值
本研究纳入445例患者的445个甲状腺结节,按直径分为≤10 mm、10-20 mm和>20 mm三组,以病理结果为参考标准,比较常规超声与剪切波弹性成像(SWE)的诊断效能。恶性结节平均弹性值在各大小组均高于良性结节,但组间弹性值差异无统计学意义;常规超声联合SWE对≤10 mm结节特异度更高,对>10 mm结节敏感度更高。
要点
- 恶性结节平均弹性值在各大小组均高于良性结节
- ≤10 mm组常规超声联合SWE特异度显著高于10-20 mm和>20 mm组
- 10-20 mm和>20 mm组常规超声联合SWE敏感度显著高于≤10 mm组
核心结论
- 常规超声联合SWE对10 mm及以下结节获得更高特异度,对大于10 mm结节获得更高敏感度。
研究设计与样本
- 研究纳入445例患者的445个甲状腺结节,按直径分为≤10 mm组、10-20 mm组和>20 mm组。
- 以病理结果为参考标准,比较常规超声与SWE的诊断效能;SWE自动计算整个病灶的平均弹性指数,良恶性鉴别阈值由受试者工作特征曲线分析构建。
诊断标准与关键数值
- 恶性结节平均弹性值在各大小组均显著高于良性结节。
- 常规超声联合SWE的特异度:≤10 mm组77.8%,10-20 mm组62.9%,>20 mm组53.3%,≤10 mm组显著高于另两组(P < .05)。
- 常规超声联合SWE的敏感度:10-20 mm组92.4%、>20 mm组94.3%,均显著高于≤10 mm组的80.7%(P < .05)。
- 加入SWE后,≤10 mm组特异度升高、敏感度和诊断准确率降低,10-20 mm组和>20 mm组敏感度升高、特异度降低,但差异均无统计学意义。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We aimed to investigate the diagnostic performance of shear wave elastography (SWE) combined with conventional ultrasonography (US) for differentiating between benign and malignant thyroid nodules of different sizes.
METHODS: A total of 445 thyroid nodules from 445 patients were divided into 3 groups based on diameter (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm). The mean elasticity index of the whole lesion was automatically calculated, and the threshold for differentiation between benign and malignant nodules was constructed by a receiver operating characteristic curve analysis. Diagnostic performances of conventional US and SWE were compared by using pathologic results as reference standards.
RESULTS: The mean elasticity was significantly higher in malignant versus benign nodules for all size groups. The differences in mean elasticity in the size groups were not statistically significant for malignant or benign nodules. The specificity of US combined with SWE for group 1 was significantly higher than that for groups 2 and 3 (77.8% versus 62.9% and 53.3%; P < .05), and compared with group 1, the sensitivity was significantly higher for groups 2 and 3 (92.4% and 94.3% versus 80.7%; P < .05). When SWE was added, the specificity increased and the sensitivity and diagnostic accuracy decreased for group 1, and the sensitivity increased and the specificity decreased for groups 2 and 3; however, the differences were not significant.
CONCLUSIONS: Combined with SWE, US yielded higher specificity for nodules of 10 mm and smaller and higher sensitivity for nodules larger than 10 mm.
引用
- Wang F, Chang C, Chen M, et al. Does Lesion Size Affect the Value of Shear Wave Elastography for Differentiating Between Benign and Malignant Thyroid Nodules? J Ultrasound Med. 2017. PMID: 28906009. doi:10.1002/jum.14367
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。