文献速递甲状腺与浅表US

对转诊活检的甲状腺结节患者评估虚拟触诊组织成像定量技术与超声甲状腺影像报告和数据系统

Assessment of Virtual Touch Tissue Imaging Quantification and the Ultrasound Thyroid Imaging Reporting and Data System in Patients With Thyroid Nodules Referred for Biopsy.
PubMed 文献 · J Ultrasound Med · 2017-09-28

研究纳入187例患者共197个经手术或细胞学证实的甲状腺结节,比较常规超声TI-RADS、VTIQ及两者联合的诊断效能。VTIQ平均剪切波速度以2.90 m/s为截断值时敏感度71.4%、特异度82.8%;将TI-RADS 4a类中平均SWV≤2.90 m/s者降为3类后,特异度由20.1%升至47.0%(P < .001)而敏感度无损失,作者认为联合VTIQ可提高TI-RADS特异度。

要点

  • VTIQ平均剪切波速度截断值2.90 m/s,敏感度71.4%、特异度82.8%。
  • TI-RADS 4a类中平均SWV≤2.90 m/s者降为3类,特异度由20.1%升至47.0%(P < .001),敏感度无损失。
  • 常规超声TI-RADS敏感度98.4%、特异度20.1%。

核心结论

  • 附加应用VTIQ可在不损失敏感度的情况下提高TI-RADS评估甲状腺结节的特异度。

研究设计与样本

  • 共纳入187例患者197个经手术或细胞学证实的甲状腺结节;结节经常规超声和VTIQ检查并归类为超声TI-RADS类别,VTIQ剪切波速度截断值由受试者工作特征曲线分析获得,比较常规超声、VTIQ及两者联合的诊断效能。

诊断标准与关键数值

  • 常规超声TI-RADS敏感度98.4%、特异度20.1%。
  • 平均、最大、最小剪切波速度及比值的受试者工作特征曲线下面积分别为0.818、0.805、0.799、0.728。
  • 平均剪切波速度截断值2.90 m/s时敏感度71.4%、特异度82.8%。
  • 以平均SWV≤2.90 m/s为标准将TI-RADS 4a类降为3类后,特异度由20.1%升至47.0%(P < .001),敏感度无损失。

临床应用与阅片要点

  • 对TI-RADS 4a类结节,可参考平均SWV≤2.90 m/s将类别降为3类,以提高特异度而不损失敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic performance of Virtual Touch tissue imaging quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA) in combination with the Thyroid Imaging Reporting and Data System (TI-RADS) for assessing thyroid nodules referred for biopsy.

METHODS: A total of 197 surgically or cytologically proven thyroid nodules in 187 patients were included. Nodules evaluated by conventional ultrasound (US) and VTIQ examinations were classified into US TI-RADS categories. The shear wave velocity (SWV) on VTIQ was assessed, and the cutoff value was obtained from a receiver operating characteristic curve analysis. Diagnostic performances of conventional US, VTIQ, and their combination were compared.

RESULTS: There were 134 benign and 63 malignant nodules. The sensitivity and specificity for the US TI-RADS were 98.4% and 20.1%, respectively. The areas under the receiver operating characteristic curves for the mean, maximum, minimum, and ratio of the SWV were 0.818, 0.805, 0.799, and 0.728. With a cutoff value of 2.90 m/s, the sensitivity and specificity of the mean SWV were 71.4% and 82.8%. By applying this value or less as a standard for downgrading TI-RADS category 4a to category 3 lesions, the specificity significantly rose from 20.1% to 47.0% (P < .001) without a loss of sensitivity.

CONCLUSIONS: The additional application of VTIQ can improve the specificity of the TI-RADS for evaluating thyroid nodules without a loss of sensitivity.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Mao F, Xu HX, Zhou H, et al. Assessment of Virtual Touch Tissue Imaging Quantification and the Ultrasound Thyroid Imaging Reporting and Data System in Patients With Thyroid Nodules Referred for Biopsy. J Ultrasound Med. 2017. PMID: 28960465. doi:10.1002/jum.14413

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。