文献速递甲状腺与浅表介入US

甲状腺结节热消融:射频消融、微波消融与高强度聚焦超声是否同样安全有效?

Thermal ablation of thyroid nodules: are radiofrequency ablation, microwave ablation and high intensity focused ultrasound equally safe and effective methods?
PubMed 文献 · Eur Radiol · 2017-09-11

本研究比较94例患者共118个良性有症状甲状腺结节在射频消融、微波消融或高强度聚焦超声后三个月的体积缩小情况。射频消融组结节体积缩小50%(p<0.05),微波消融组缩小44%(p<0.05),高强度聚焦超声组缩小48%(p<0.05),三种方法均未导致严重或永久性并发症,作者认为三种方法效果相当且安全有效。

要点

  • 射频消融、微波消融与高强度聚焦超声后三个月结节体积分别缩小50%、44%和48%(均p<0.05)
  • 三种热消融方法均未导致严重或永久性并发症,作者认为均可作为甲状腺切除术或放射性碘治疗的替代选择
  • 高强度聚焦超声仅用于14例小结节患者,射频消融与微波消融各40例,分组基于两种方法效果相当的假设

核心结论

  • 射频消融、微波消融与高强度聚焦超声在结节体积缩小方面结果相当,三种方法均为良性甲状腺结节安全有效的治疗方式,可作为甲状腺切除术或放射性碘治疗的替代选择。

研究设计与样本

  • 共纳入94例患者(39男、55女)的118个良性有症状甲状腺结节,分为三个亚组:高强度聚焦超声组14例小结节患者,射频消融组与微波消融组各40例(分组基于两种方法效果相当的假设);消融前与消融后体积均由超声测量。

关键影像表现/征象

  • 消融后三个月超声测量显示射频消融组结节体积缩小50%(p<0.05)
  • 消融后三个月超声测量显示微波消融组结节体积缩小44%(p<0.05)
  • 消融后三个月超声测量显示高强度聚焦超声组结节体积缩小48%(p<0.05)

诊断标准与关键数值

  • 射频消融组结节体积缩小50%(p<0.05)
  • 微波消融组结节体积缩小44%(p<0.05)
  • 高强度聚焦超声组结节体积缩小48%(p<0.05)

临床应用与阅片要点

  • 作者认为射频消融、微波消融与高强度聚焦超声均可作为良性甲状腺结节安全有效的治疗选择,并可作为甲状腺切除术或放射性碘治疗的替代方案。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study compares volume reduction of benign thyroid nodules three months after Radiofrequency Ablation (RFA), Microwave Ablation (MWA) or High Intensity Focused Ultrasound (HIFU) to evaluate which of these methods is the most effective and safe alternative to thyroidectomy or radioiodine therapy.

MATERIAL AND METHODS: Ninety-four patients (39 male, 55 female) with a total of 118 benign, symptomatic thyroid nodules were divided into three subgroups. HIFU was applied to 14 patients with small nodules. The other 80 patients were divided up into two groups of 40 patients each for RFA and MWA in the assumption that both methods are comparable effective. The pre-ablative and post-ablative volume was measured by ultrasound.

RESULTS: RFA showed a significant volume reduction of nodules of 50 % (p<0.05), MWA of 44 % (p<0.05) and HIFU of 48 % (p<0.05) three months after ablation. None of the examined ablation techniques caused serious or permanent complications.

CONCLUSION: RFA, MWA and HIFU showed comparable results considering volume reduction. All methods are safe and effective treatments of benign thyroid nodules.

KEY POINTS: • Thermal Ablation can be used to treat benign thyroid nodules • Thermal Ablation can be an alternative to thyroidectomy or radioiodine therapy • Radiofrequency Ablation, Microwave Ablation, High Intensity Focused Ultrasound are safe and effective.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Korkusuz Y, Gröner D, Raczynski N, et al. Thermal ablation of thyroid nodules: are radiofrequency ablation, microwave ablation and high intensity focused ultrasound equally safe and effective methods? Eur Radiol. 2017. PMID: 28894936. doi:10.1007/s00330-017-5039-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。