高分辨率超声对Nω-硝基-L-精氨酸甲酯盐酸盐诱导的子痫前期样症状小鼠模型血管功能障碍的系统性评估

Systemic Evaluation of Vascular Dysfunction by High-Resolution Sonography in an Nω -Nitro-l-Arginine Methyl Ester Hydrochloride-Induced Mouse Model of Preeclampsia-Like Symptoms.
PubMed 文献 · J Ultrasound Med · 2017-09-15

本研究用高分辨率超声评估L-NAME诱导的子痫前期样症状孕鼠的血管功能,发现L-NAME组子宫胎盘及脐动脉RI和PI显著升高、股动脉血流介导舒张降低;子宫胎盘及脐动脉RI和PI与胎重及头臀长负相关;120秒血流介导舒张是独立诊断指标,AUC为0.934,最佳截断值11.1%,敏感度100%、特异度84.6%。

要点

  • L-NAME组子宫胎盘及脐动脉RI和PI较对照组显著升高。
  • L-NAME组股动脉血流介导舒张较对照组降低。
  • 120秒血流介导舒张诊断子痫前期样模型的AUC为0.934,截断值11.1%。

核心结论

  • 子宫胎盘及脐动脉PI和RI可识别「高危」妊娠胎儿,血流介导舒张是预测子痫前期的可靠指标;高分辨率超声评估血管功能为子痫前期相关基础研究提供可重复性高的有用平台。

研究设计与样本

  • 研究论文;孕鼠在妊娠第7至18天皮下注射生理盐水(对照组,n=10)或L-NAME(n=10);用高频超声测量子宫胎盘、脐、股及颈总动脉的RI和PI以及股动脉血流介导舒张。

关键影像表现/征象

  • L-NAME组子宫胎盘及脐动脉RI和PI较对照组显著升高。
  • L-NAME组股动脉血流介导舒张较对照组降低。
  • 子宫胎盘及脐动脉RI和PI与胎重及头臀长呈负相关。

诊断标准与关键数值

  • 多变量logistic回归分析显示120秒血流介导舒张是L-NAME诱导子痫前期样模型的独立诊断标准。
  • ROC分析显示120秒血流介导舒张的AUC最大为0.934,最佳截断值11.1%,敏感度100%、特异度84.6%。

临床应用与阅片要点

  • 子宫胎盘及脐动脉PI和RI可用于识别「高危」妊娠胎儿。
  • 血流介导舒张可作为预测子痫前期的可靠指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to evaluate vascular function, including arterial resistance and endothelial function, by high-resolution sonography in an Nω -nitro-l-arginine methyl ester hydrochloride (l-NAME)-induced mouse model of preeclampsia-like symptoms.

METHODS: Pregnant mice were subcutaneously injected with a saline solution (control; n = 10) or l-NAME (n = 10) between the 7th and 18th days of gestation. The resistive index and pulsatility index (RI and PI, indicators of arterial resistance) of the uteroplacental, umbilical, femoral, and common carotid arteries and the flow-mediated dilatation (index of endothelial function) of the femoral artery were measured by high-frequency sonography in both groups.

RESULTS: We noted significant increases in the RI and PI of the uteroplacental and umbilical arteries and a decrease in the flow-mediated dilatation of the femoral artery in the l-NAME group compared with the control group. We also found that the RI and PI of the uteroplacental and umbilical arteries were negatively correlated with fetal weight and crown-rump length. The results of the multivariate analysis using a logistic regression model indicated that the flow-mediated dilatation at 120 seconds was an independent diagnostic criterion for the l-NAME-induced preeclampsia-like model. A receiver operating characteristic analysis showed that flow-mediated dilatation at 120 seconds had the greatest area under the curve of 0.934, with an optimal cutoff point of 11.1%, yielding sensitivity of 100% and specificity of 84.6%.

CONCLUSIONS: The PI and RI of the fetomaternal vasculature can identify fetuses in "high-risk" pregnancies, and flow-mediated dilatation is a reliable indicator for predicting preeclampsia. Assessment of vascular function by high-resolution sonography provides a useful platform for preeclampsia-related basic research with high reproducibility.

来源:J Ultrasound Med,查看原文。版权归原作者所有。