文献速递妇产影像US

宫颈长度缩短速率在血管前置管理中的作用

The Rate of Cervical Length Shortening in the Management of Vasa Previa.
PubMed 文献 · J Ultrasound Med · 2017-09-07

本研究回顾性分析29例孕中期诊断血管前置的单胎妊娠,比较择期与急诊剖宫产两组宫颈长度缩短速率,发现择期组缩短速率显著更慢(中位数0.7 vs 1.5 mm/周,P=0.011),宫颈长度每多缩短1 mm/周,急诊剖宫产风险增加6.50倍(95%CI 1.02-41.20),预测急诊剖宫产的AUC为0.85(95%CI 0.69-0.99),作者认为宫颈长度缩短速率与急诊剖宫产风险相关,需多中心研究进一步验证。

要点

  • 孕中期诊断血管前置者,宫颈长度缩短速率越快,急诊剖宫产风险越高。
  • 择期剖宫产组宫颈长度缩短速率中位0.7 mm/周,急诊剖宫产组中位1.5 mm/周(P=0.011)。
  • 宫颈长度缩短速率预测急诊剖宫产的AUC为0.85(95%CI 0.69-0.99)。

核心结论

  • 孕中期诊断血管前置的单胎妊娠中,宫颈长度缩短速率与急诊剖宫产风险相关,宫颈长度每多缩短1 mm/周,急诊剖宫产风险增加6.50倍(95%CI 1.02-41.20);作者认为需多中心研究前瞻性验证该数据,特别是系列宫颈长度测量在决定个体化最佳分娩时机中的作用。

研究设计与样本

  • 回顾性病例对照研究,纳入29例孕中期产前诊断血管前置的单胎妊娠,均经阴道超声系列测量宫颈长度,按分娩方式分为择期剖宫产组14例和急诊剖宫产组15例。

关键影像表现/征象

  • 择期剖宫产组宫颈长度缩短速率中位0.7 mm/周(范围0.1-2.0),急诊剖宫产组中位1.5 mm/周(范围0.25-3.0),择期组显著更慢(P=0.011)。
  • 宫颈长度缩短速率预测急诊剖宫产的受试者工作特征曲线下面积为0.85(95%CI 0.69-0.99)。

诊断标准与关键数值

  • 宫颈长度缩短速率预测急诊剖宫产的AUC为0.85(95%CI 0.69-0.99)。
  • 宫颈长度每多缩短1 mm/周,急诊剖宫产的比值比为6.50(95%CI 1.02-41.20)。

临床应用与阅片要点

  • 对孕中期诊断血管前置的单胎妊娠,系列经阴道超声测量宫颈长度并计算缩短速率,可能有助于评估急诊剖宫产风险。
  • 作者认为需多中心研究前瞻性验证数据,尤其系列宫颈长度测量在决定个体化最佳分娩时机中的作用。

局限性

  • 原文结论指出需进一步多中心研究以前瞻性验证数据。
  • 原文结论指出尤其需验证系列宫颈长度测量在决定个体病例最佳分娩时机中的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: There is no consensus about the optimal surveillance strategy in women with a diagnosis of vasa previa. The aim of this study was to evaluate the role of the rate of change in cervical length measurements in the management of singleton pregnancies with a diagnosis of vasa previa.

METHODS: We performed a retrospective case-control study of our databases for pregnancies with a prenatal diagnosis of vasa previa that were followed with transvaginal sonography for cervical length and evaluated the impact of the changes in cervical length on the need for emergency cesarean delivery.

RESULTS: The cohort included 29 singleton pregnancies with a prenatal diagnosis of vasa previa in the second trimester. There were 14 and 15 pregnancies that underwent elective and emergency cesarean delivery, respectively. The rate of cervical length shortening was significantly slower for women with elective compared to emergency cesarean delivery (median [range], 0.7 [0.1-2.0] versus 1.5 [0.25-3.0] mm/wk; P = .011). For each additional millimeter-per-week decrease in cervical length, the odds of emergency cesarean delivery increased by 6.50 (95% confidence interval, 1.02-41.20). The receiver operating characteristic curve for the rate of cervical length shortening in the prediction of emergency cesarean delivery yielded an area under the curve of 0.85 (95% confidence interval, 0.69-0.99).

CONCLUSIONS: Our findings indicate an association between the rate of cervical length shortening and the risk of emergency cesarean delivery in pregnancies with a diagnosis of vasa previa in the second trimester. Further multicentric studies are required to validate our data prospectively and, in particular, the role of serial cervical length measurements in determining the optimal delivery time for individual cases.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Maymon R, Melcer Y, Tovbin J, et al. The Rate of Cervical Length Shortening in the Management of Vasa Previa. J Ultrasound Med. 2017. PMID: 28880409. doi:10.1002/jum.14411

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。