文献速递泌尿生殖MR

PI-RADS 第2版与第1版在阅片者间一致性和临床显著前列腺癌检出诊断准确性方面的直接比较

Direct comparison of PI-RADS version 2 and version 1 regarding interreader agreement and diagnostic accuracy for the detection of clinically significant prostate cancer.
PubMed 文献 · Eur J Radiol · 2017-07-21

纳入67例接受前列腺MRI及后续经会阴模板穿刺活检的患者,由两家机构的4名阅片者分别使用PI-RADS v1和v2独立评分。v2的DCE评分阅片者间一致性良好(ICC=0.70),略高于v1(ICC=0.64);DWI评分和最终PI-RADS评分的一致性几乎相同(ICC均为0.71和0.76/0.77)。各阅片者诊断准确性在v1与v2间无显著差异(p=0.09-0.93,AZ范围0.78-0.88)。

要点

  • PI-RADS v2与v1的最终评分阅片者间一致性几乎相同(ICC均为0.71)。
  • v2的DCE评分一致性良好(ICC=0.70),略高于v1(ICC=0.64)。
  • 各阅片者诊断准确性在v1与v2间无显著差异(p=0.09-0.93,AZ范围0.78-0.88)。

核心结论

  • PI-RADS v2与v1的阅片者间一致性相似,诊断性能相当;v2对DCE解读的简化可能略微提高一致性,且未对诊断性能产生负面影响。

研究设计与样本

  • 共纳入67例患者(中位年龄65.3岁,范围51.2-78.2岁;PSA 6.8μg/L,范围0.2-33μg/L),均在接受前列腺MRI后≤6个月内行经会阴模板穿刺活检;来自两家机构的4名阅片者在间隔≥3个月的两次独立阅片会话中分别使用PI-RADS v1和v2评估前列腺癌可能性。

诊断标准与关键数值

  • 阅片者间一致性采用组内相关系数(ICC)评估,差异显著性以95%置信区间不重叠为准。
  • DCE评分ICC:v2为0.70(95%CI 0.66-0.74),v1为0.64(95%CI 0.59-0.69)。
  • DWI评分ICC:v1为0.77,v2为0.76。
  • 每个象限最终PI-RADS评分ICC:v1与v2均为0.71。
  • 诊断准确性采用受试者工作特征曲线下面积(AZ)评估,p<0.05为统计学显著;各阅片者AZ范围0.78-0.88,v1与v2间p=0.09-0.93。

临床应用与阅片要点

  • v2对DCE解读的简化可能略微提高阅片者间一致性,且未对诊断性能产生负面影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: to simultaneously evaluate interreader agreement and diagnostic accuracy in the of PI-RADS v2 and compare it to v1.

METHODS: A total of 67 patients (median age 65.3 y, range 51.2-78.2 y; PSA 6.8μg/L, 0.2-33μg/L) undergoing MRI of the prostate and subsequent transperineal template biopsy within ≤6 months from MRI were included. Four readers from two institutions evaluated the likelihood of prostate cancer using PI-RADS v1 and v2 in two separate reading sessions ≥3 months apart. Interreader agreement was assessed for each pulse-sequence and for total PI-RADS scores using the intraclass correlation coefficient (ICC). Differences were considered significant for non-overlapping 95%-confidence intervals. Diagnostic accuracy was assessed with the area under the receiver operating characteristic curve (AZ). A p-value <0.05 was considered statistically significant.

RESULTS: Interreader agreement for DCE-scores was good in v2 (ICC2=0.70; 95% CI: 0.66-0.74) and slightly lower in v1 (ICC1=0.64, 0.59-0.69). Agreement for DWI scores (ICC1=0.77, ICC2=0.76) as well as final PI-RADS scores per quadrant were nearly identical (ICC1=ICC2=0.71). Diagnostic accuracy showed no significant differences (p=0.09-0.93) between v1 and v2 in any of the readers (range: AZ=0.78-0.88).

CONCLUSION: PI-RADS scores show similar interreader agreement in v2 and v1 at comparable diagnostic performance. The simplification of the DCE interpretation in v2 might slightly improve agreement while not negatively affecting diagnostic performance.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Becker AS, Cornelius A, Reiner CS, et al. Direct comparison of PI-RADS version 2 and version 1 regarding interreader agreement and diagnostic accuracy for the detection of clinically significant prostate cancer. Eur J Radiol. 2017. PMID: 28941761. doi:10.1016/j.ejrad.2017.07.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。