文献速递泌尿生殖腹部MR

高b值与标准b值DWI检测前列腺癌的头对头比较:系统评价与Meta分析

Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis.
PubMed 文献 · AJR Am J Roentgenol · 2017-09-27

该系统评价与Meta分析纳入11项研究共789例患者,以组织病理学为参考标准,头对头比较高b值(>1000 s/mm²)与标准b值(800-1000 s/mm²)DWI对前列腺癌的检出效能。高b值DWI的汇总敏感度(0.80)和特异度(0.92)均显著高于标准b值DWI(敏感度0.78,特异度0.87)。亚组分析显示高b值DWI特异度 consistently 更高,敏感度仅在外周带、移行带、多参数方案、视觉评估和病灶分析亚组中显著更高。

要点

  • 高b值DWI(>1000 s/mm²)检测前列腺癌的汇总敏感度0.80、特异度0.92,均优于标准b值DWI。
  • 标准b值DWI(800-1000 s/mm²)汇总敏感度0.78、特异度0.87,特异度低于高b值DWI。
  • 高b值DWI特异度在各亚组中持续更高,敏感度优势仅见于部分亚组。

核心结论

  • 头对头比较显示,高b值DWI检测前列腺癌的敏感度和特异度均显著优于标准b值DWI;亚组分析中高b值DWI特异度持续更优。

研究设计与样本

  • 系统评价与Meta分析,检索MEDLINE和EMBASE数据库至2017年4月1日,纳入11项以组织病理学为参考标准的诊断准确性研究,共789例患者,采用修订版QUADAS工具评估方法学质量。

诊断标准与关键数值

  • 高b值DWI(>1000 s/mm²)汇总敏感度0.80(95%CI 0.70-0.87),汇总特异度0.92(95%CI 0.87-0.95)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm2) and standard-b-value (800-1000 s/mm2) DWI regarding diagnostic performance in the detection of prostate cancer.

MATERIALS AND METHODS: The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI.

RESULTS: Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04).

CONCLUSION: In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Woo S, Suh CH, Kim SY, et al. Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2017. PMID: 28952806. doi:10.2214/AJR.17.18480

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。