移植肾动脉狭窄筛查:基于超声的狭窄概率分层
研究纳入120例有肾功能不全临床征象的患者,评估5项频谱多普勒超声参数对移植肾动脉狭窄的诊断价值并建立预测模型。全模型敏感度和特异度分别为97%和91%,简化模型基于最高肾动脉流速、远端频谱增宽和加速时间,可将患者分为低、中、高和极高四个风险类别。
要点
- 简化模型仅用最高肾动脉流速、远端频谱增宽和加速时间三项参数进行风险分层。
- 简化模型敏感度和特异度分别为96%和83%,可将患者分为四个风险类别。
- 全模型纳入5项超声变量,敏感度和特异度分别为97%和91%。
核心结论
- 作者提出基于最高肾动脉流速、远端频谱增宽和加速时间的简化模型,用于将患者分为移植肾动脉狭窄的低、中、高和极高风险类别。
研究设计与样本
- 研究纳入2005年1月至2015年12月间120例有肾功能不全临床征象的患者,均行超声检查后行血管造影(数字减影血管造影或MR血管造影)。
诊断标准与关键数值
- 全模型(5项变量)敏感度97%、特异度91%;简化变量模型排除比值和阻力指数变量后敏感度和特异度未受影响。
临床应用与阅片要点
- 简化模型应用截断值后敏感度96%、特异度83%,可将患者分为移植肾动脉狭窄低、中、高和极高四个风险类别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The objective of our study was to evaluate which spectral Doppler ultrasound parameters are useful in patients with clinical concern for transplant renal artery stenosis (TRAS) and create mathematically derived prediction models that are based on these parameters.
MATERIALS AND METHODS: The study subjects included 120 patients with clinical signs of renal dysfunction who had undergone ultrasound followed by angiography (either digital subtraction angiography or MR angiography) between January 2005 and December 2015. Five ultrasound variables were evaluated: ratio of highest renal artery velocity to iliac artery velocity, highest renal artery velocity, spectral broadening, resistive indexes, and acceleration time. Angiographic studies were categorized as either showing no stenosis or showing stenosis. Reviewers assessed the ultrasound examinations for TRAS using all five variables, which we refer to as the full model, and using a reduced number of variables, which we refer to as the reduced-variable model; sensitivities and specificities were generated.
RESULTS: Ninety-seven patients had stenosis and 23 had no stenosis. The full model had a sensitivity and specificity of 97% and 91%, respectively. The reduced-variable model excluded the ratio and resistive index variables without affecting sensitivity and specificity. We applied cutoff values to the variables in the reduced-variable model, which we refer to as the simple model. Using these cutoff values, the simple model showed a sensitivity and specificity of 96% and 83%. The simple model was able to categorize patients into four risk categories for TRAS: low, intermediate, high, and very high risk.
CONCLUSION: We propose a simple model that is based on highest renal artery velocity, distal spectral broadening, and acceleration time to classify patients into risk categories for TRAS.
引用
- Fananapazir G, McGahan JP, Corwin MT, et al. Screening for Transplant Renal Artery Stenosis: Ultrasound-Based Stenosis Probability Stratification. AJR Am J Roentgenol. 2017. PMID: 28858538. doi:10.2214/AJR.17.17913
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。