计算机断层扫描诊断胃胃瘘的定量方法
回顾性分析12例Roux-en-Y胃旁路术后患者共13次CT,以消化道造影为金标准,计算残胃与胃小囊CT值比值,发现瘘组比值1.12±0.29高于反流组0.56±0.19(P<0.05),比值0.8诊断胃胃瘘敏感度100%、特异度78.6%。
要点
- Roux-en-Y胃旁路术后CT鉴别胃胃瘘与反流,可计算残胃与胃小囊CT值比值(RA)。
- RA比值最佳阈值0.8,诊断胃胃瘘敏感度100%、特异度78.6%,特异度低于定性评估的89.2%。
- 结合RA比值后放射科医师最终结论敏感度58.3%、特异度100%,高于初始定性评估的45.8%和89.2%。
核心结论
- 口服对比剂在残胃与胃小囊的相对衰减比值(RA)可帮助CT鉴别胃胃瘘与口服对比剂反流至胆胰支,瘘组RA比值1.12±0.29高于反流组0.56±0.19(P<0.05)。
研究设计与样本
- 回顾性研究,12例Roux-en-Y胃旁路术后患者共13次CT,均有口服对比剂,2名放射科医师评估,以上消化道造影(UGI)为金标准。
关键影像表现/征象
- CT上胃胃瘘的表现为口服对比剂从胃小囊进入残胃,需与对比剂反流至胆胰支鉴别。
- 定量指标为残胃与胃小囊的CT值比值(RA比值),瘘组1.12±0.29,反流组0.56±0.19。
诊断标准与关键数值
- UGI诊断胃胃瘘:13次检查中6次(46.2%)显示胃胃瘘。
- RA比值=残胃CT值/胃小囊CT值;两组比值差异有统计学意义(P<0.05)。
- ROC分析确定RA比值阈值为0.8,诊断胃胃瘘敏感度100%、特异度78.6%。
- 初始定性评估诊断胃胃瘘敏感度45.8%、特异度89.2%。
- 结合RA比值后放射科医师最终结论敏感度58.3%、特异度100%。
临床应用与阅片要点
- 在Roux-en-Y胃旁路术后患者CT中,可计算残胃与胃小囊的RA比值来辅助鉴别胃胃瘘与口服对比剂反流。
- RA比值0.8作为诊断胃胃瘘的阈值,敏感度100%、特异度78.6%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine if the attenuation of contrast material in the excluded stomach compared with the gastric pouch is helpful in diagnosing gastrogastric (GG) fistula.
MATERIALS AND METHODS: In a retrospective study, 13 CT scans in 12 patients (age 43.2 ± 9.2, 10 females) who had undergone Roux-en-Y gastric bypass and who had oral contrast in both the gastric pouch and excluded stomach were qualitatively and quantitatively evaluated for GG fistula by two radiologists, using upper GI series (UGI) as the gold standard. Quantitative analysis was performed by computing the relative attenuation (RA) ratio (HU in excluded stomach/HU in gastric pouch). Statistical analysis was performed to determine if the RA ratio values correlated with the UGI findings of GG fistula.
RESULTS: 46.2% (6/13) of UGI studies demonstrated a GG fistula. Statistical analysis demonstrated a significant difference in RA ratio (P < 0.05) between the fistula group (1.12 ± 0.29) and the reflux group (0.56 ± 0.19). A receiver operating characteristic analysis identified an RA ratio of 0.8 that maximized sensitivity (100%), at the expense of specificity (78.6%), for diagnosing GG fistula. In contrast, the initial qualitative evaluation for GG fistula yielded a lower sensitivity (45.8%) and a higher specificity (89.2%). After taking RA ratios into account, radiologists' final conclusions achieved higher sensitivity (58.3%) and specificity (100%).
CONCLUSION: The relative attenuation ratio of oral contrast in the excluded stomach versus the gastric pouch can be a reliable tool in differentiating GG fistula from oral contrast reflux up the biliopancreatic limb on CT.
引用
- Gao G, Nezami N, Mathur M, et al. Diagnosis of gastrogastric fistula on computed tomography: a quantitative approach. Abdom Radiol (NY). 2018. PMID: 28884370. doi:10.1007/s00261-017-1304-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。