肝脏恶性肿瘤射频消融后即刻非增强磁共振成像:初步结果
前瞻性研究评估经皮超声引导射频消融肝脏恶性肿瘤后同日非增强MRI预测随访CT疗效的准确性,共23个病灶(20个肝细胞癌和3个转移瘤)。脂肪饱和T1加权序列显示凝固性坏死最佳,MRI预测病灶中心定位准确和完全治疗的敏感度均为100%,结论认为单序列fs T1-w MRI高度准确,可避免不完全治疗时不必要的CT。
要点
- 射频消融后同日非增强MRI中,脂肪饱和T1加权序列显示消融区凝固性坏死最清晰。
- fs T1-w序列上凝固性坏死呈高信号者占17/23(74%)。
- MRI预测病灶中心定位准确的敏感度100%、特异度75%、阳性预测值95%、阴性预测值100%、准确率100%。
核心结论
- 与随访CT对照,单序列fs T1-w非增强MRI预测经皮消融肝脏恶性肿瘤疗效高度准确,可避免不完全治疗时不必要的CT。
研究设计与样本
- 前瞻性研究,对23个肝脏恶性肿瘤(20个肝细胞癌和3个转移瘤)行经皮超声引导射频消融,术后同日行非增强MRI,以1个月随访CT为参考标准。
关键影像表现/征象
- 脂肪饱和T1加权序列是显示消融区最清晰的序列。
- 凝固性坏死在fs T1-w序列上呈高信号者17/23(74%)。
诊断标准与关键数值
- MRI预测病灶中心定位准确:敏感度100%、特异度75%、阳性预测值95%、阴性预测值100%、准确率100%(19/20个病灶)。
- MRI预测病灶完全治疗:敏感度100%、特异度100%、阳性预测值100%、阴性预测值100%、准确率100%(17/17个病灶)。
临床应用与阅片要点
- 射频消融后同日可行非增强MRI单序列fs T1-w评估消融区,预测病灶中心定位和完全治疗。
- 原文结论认为与随访CT对照高度准确,可避免不完全治疗时不必要的CT。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the accuracy of unenhanced magnetic resonance imaging (MRI) immediately after the percutaneous ultrasound-guided radiofrequency ablation (RFA) of liver malignancy in predicting treatment efficacy at CT follow-up.
MATERIALS AND METHODS: Percutaneous ablation was prospectively performed in 23 liver malignancies (20 hepatocarcinomas and 3 metastases). After the procedure in the same day all patients were studied with unenhanced MRI. The best sequence to detect the coagulative necrosis was visually established. Pre-RFA CT and post-RFA MRI were registered with non-rigid transformation algorithm. Manual segmentation of lesions and ablated areas in pre-RFA CT, post-RFA MRI, and follow-up CT were obtained. Sensitivity, specificity, positive predictive value (PPV), negative predicitve value (NPV), and accuracy of MRI in predicting the correct centering and the complete treatment of the lesion were calculated in respect to the 1-month follow-up CT.
RESULTS: Fat-saturated T1-weighted (fs T1-w) was the sequence in which the best conspicuity of the ablated area was depicted. Coagulative necrosis was hyperintense in fs T1-w sequence in 17/23 (74%). In respect to follow-up CT, MRI predicted the correct centering of the lesions in 19/20 lesions with sensitivity, specificity, PPV, NPV, and accuracy of 100%, 75%, 95%, 100%, and 100%, respectively. MRI predicted the complete treatment of the lesions in 17/17 lesions with sensitivity, specificity, PPV, NPV, and accuracy of 100%.
CONCLUSION: MRI with the single fs T1-w sequence was highly accurate in predicting the treatment efficacy of percutaneous ablation of liver malignancies in comparison to follow-up CT control. Unnecessary CT in case of incomplete treatment can be therefore easily avoided.
引用
- D'Onofrio M, Cardobi N, Ruzzenente A, et al. Unenhanced magnetic resonance imaging immediately after radiofrequency ablation of liver malignancy: preliminary results. Abdom Radiol (NY). 2018. PMID: 28861631. doi:10.1007/s00261-017-1299-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。