胎儿腹腔内脐静脉瘤:回顾性队列研究及系统评价与荟萃分析
本研究回顾性分析8年间本院13例胎儿腹腔内脐静脉瘤(FIUVV)病例的超声特征与妊娠结局,并对5项研究共254例进行系统评价与荟萃分析。孤立性FIUVV预后通常良好,无染色体异常或宫内胎儿死亡(IUFD)报告;约19%病例合并其他超声异常,此类非孤立性FIUVV的染色体异常发生率为19.6%、IUFD为7.3%,风险显著高于孤立性组。
要点
- 孤立性FIUVV未见染色体异常或IUFD报告,预后通常良好。
- 约19%的FIUVV合并其他超声异常,提示需仔细扫查胎儿结构。
- 非孤立性FIUVV的染色体异常风险OR 14.8,IUFD风险OR 8.2。
核心结论
- 孤立性FIUVV的妊娠结局通常良好。
- 约20%的病例合并其他超声异常,这些异常与染色体异常和IUFD风险增加相关。
研究设计与样本
- 回顾性队列研究纳入本院8年间管理的13例FIUVV病例,采集诊断时孕周、脐静脉瘤直径、直径增长、合并超声或染色体异常及妊娠结局。
- 系统评价与荟萃分析纳入5项研究共254例FIUVV病例,评估染色体异常、小于胎龄儿和IUFD发生率,并汇总这些结局与合并超声异常关系的OR估计值。
关键影像表现/征象
- 本队列13例中2例(15.4%)发现其他超声异常,1例发生IUFD,无染色体异常或脐静脉瘤血栓形成记录。
- 荟萃分析中非孤立性FIUVV占19%(95% CI,10.9-29.1%)。
- 孤立性FIUVV胎儿中无染色体异常或IUFD报告。
诊断标准与关键数值
- 非孤立性FIUVV组染色体异常发生率为19.6%,与孤立性组相比OR为14.8(95% CI,2.9-73.0)。
- 非孤立性FIUVV组IUFD发生率为7.3%,与孤立性组相比OR为8.2(95% CI,1.05-63.1)。
临床应用与阅片要点
- 诊断FIUVV时应系统扫查胎儿其他结构,以区分孤立性与非孤立性病例。
- 非孤立性FIUVV与染色体异常和IUFD风险增加相关,孤立性FIUVV结局通常良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the ultrasound characteristics and outcome of pregnancies with fetal intra-abdominal umbilical vein varix (FIUVV).
METHODS: Cases of FIUVV managed at our tertiary university hospital over an 8-year period were reviewed. Information retrieved included gestational age and diameter of the umbilical varix at diagnosis, increase in varix diameter, associated ultrasound or chromosomal anomalies and pregnancy outcome. Furthermore, a systematic review and meta-analysis of series of FIUVV in the literature was performed to assess the incidence of chromosomal anomalies, small-for-gestational age infants and intrauterine fetal demise (IUFD), and to pool odds ratio (OR) estimates on the relationship between the incidence of these outcomes and the presence of additional associated ultrasound anomalies.
RESULTS: Thirteen cases of FIUVV were included in the cohort study. Additional ultrasound anomalies were found in two (15.4%) of 13 cases. One case of IUFD was observed and no case of chromosomal anomaly or thrombosis of varix was recorded. A total of five studies comprising 254 cases met the inclusion criteria of the systematic review. FIUVV was associated with additional ultrasound anomalies (non-isolated FIUVV) in 19% (95% CI, 10.9-29.1%) of cases. No case of chromosomal abnormality or IUFD was reported in fetuses with isolated FIUVV. In contrast, in the group of non-isolated FIUVV, the incidence of chromosomal anomalies was 19.6% and that of IUFD was 7.3%, with ORs of 14.8 (95% CI, 2.9-73.0) and 8.2 (95% CI, 1.05-63.1), respectively, when compared with the group of isolated FIUVV.
CONCLUSION: When isolated, the outcome of cases affected by FIUVV is usually favorable. In about 20% of cases, additional ultrasound anomalies are found, which are associated with an increased risk for chromosomal abnormalities and IUFD. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
引用
- di Pasquo E, Kuleva M, O'Gorman N, et al. Fetal intra-abdominal umbilical vein varix: retrospective cohort study and systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2018. PMID: 28876490. doi:10.1002/uog.18895
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。