子宫肌瘤:MRI表现与磁共振弹性成像所测硬度之间的相关性
本研究对102例有症状子宫肌瘤患者行盆腔MRI及2D-MRE检查,按T2表现将肌瘤分为四组。T2高信号肌瘤硬度显著低于T2低信号且轻度不均匀肌瘤(差值2.38 kPa,p<0.05),T2低信号且明显不均匀肌瘤硬度亦显著低于T2低信号且轻度不均匀肌瘤(差值1.25 kPa,p<0.05);T1信号及钆增强与硬度无显著关联,2D与3D MRE所测硬度无显著差异。作者认为肌瘤硬度与T2表现相关,需进一步研究其能否作为预测MR引导治疗反应的影像生物标志物。
要点
- T2高信号肌瘤硬度显著低于T2低信号且轻度不均匀肌瘤,平均差值2.38 kPa(p<0.05)。
- T2低信号且明显不均匀肌瘤硬度显著低于T2低信号且轻度不均匀肌瘤,平均差值1.25 kPa(p<0.05)。
- 肌瘤硬度与T1信号特征或钆增强无显著关联,2D与3D MRE所测硬度无显著差异。
核心结论
- 数据提示肌瘤硬度差异与不同T2影像特征相关,硬度较低者为T2高信号、硬度较高者为T2低信号;需进一步研究MRE所测肌瘤硬度能否作为影像生物标志物帮助预测MR引导治疗反应。
研究设计与样本
- 经IRB批准、符合HIPAA的前瞻性收集盆腔MRI与2D-MRE数据的回顾性分析,共纳入102例有症状子宫肌瘤患者,行T1、T2加权盆腔MRI及钆增强,小部分患者同时行2D与3D MRE评估肌瘤硬度。
关键影像表现/征象
- 按T2表现将肌瘤分为四组:等信号7例、高信号6例、低信号且轻度不均匀69例、低信号且明显不均匀20例。
- T2高信号肌瘤硬度显著低于T2低信号且轻度不均匀肌瘤,平均硬度差2.38 kPa(p<0.05)。
- T2低信号且明显不均匀肌瘤硬度显著低于T2低信号且轻度不均匀肌瘤,平均硬度差1.25 kPa(p<0.05)。
- 肌瘤硬度与T1信号特征或钆增强无显著关联。
- 2D与3D MRE所测硬度值无显著差异。
诊断标准与关键数值
- 肌瘤平均硬度为4.81 ± 2.12 kPa。
- T2高信号肌瘤较T2低信号且轻度不均匀肌瘤硬度低2.38 kPa(p<0.05)。
- T2低信号且明显不均匀肌瘤较T2低信号且轻度不均匀肌瘤硬度低1.25 kPa(p<0.05)。
临床应用与阅片要点
- 阅片时可结合T2信号特征初步判断肌瘤硬度:T2高信号者硬度较低,T2低信号且轻度不均匀者硬度较高。
- T1信号特征及钆增强与肌瘤硬度无显著关联,报告时不宜据此推断硬度。
- 2D与3D MRE所测硬度无显著差异,两种方式均可用于评估肌瘤硬度。
局限性
- 原文结论指出需进一步研究以确定MRE所测肌瘤硬度能否作为影像生物标志物帮助预测MR引导治疗反应。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Magnetic resonance elastography has proven to be a valuable tool in the diagnosis of liver fibrosis, breast and cervical cancer, but its application in uterine fibroids requires further characterization. The aim of the present study was to examine the relationship between uterine fibroid stiffness by MRE and MR imaging characteristics.
MATERIALS AND METHODS: An IRB-approved, HIPAA compliant review was performed of prospectively collected pelvic MRI and 2D-MRE data in patients with symptomatic uterine fibroids (N = 102). T1 and T2 weighted pelvic MRI with gadolinium enhancement were performed. In a small patient subset, fibroid stiffness was assessed by both 2D and 3D MRE. Fibroid stiffness by modality or imaging characteristics was analyzed using one-way analysis of variance followed by Student t test.
RESULTS: Four fibroid groups were identified based on T2 appearance: Isointense (N = 7), bright (N = 6), dark with minimal heterogeneity (N = 69), and dark with substantial heterogeneity (N = 20). Mean fibroid stiffness was 4.81 ± 2.12 kPa. Comparison of fibroid stiffness by T2 signal intensity showed that T2 bright fibroids were significantly less stiff than fibroids appearing T2 dark with minimal heterogeneity (mean stiffness difference = 2.38 kPa; p < 0.05) and T2 dark fibroids with substantial heterogeneity were significantly less stiff than T2 dark fibroids with minimal heterogeneity (mean difference = 1.25 kPa; p < 0.05). There was no significant association between fibroid stiffness and T1 signal characteristics or gadolinium enhancement. There was no significant difference in stiffness values obtained by either 2D vs. 3D MRE.
CONCLUSIONS: These data suggest differences in fibroid stiffness are associated with different T2 imaging characteristics with less stiff fibroids being T2 bright and more stiff fibroids being T2 dark. Further studies are needed to determine if fibroid stiffness by MRE may serve as an imaging biomarker to help predict MR-guided treatment response.
引用
- Jondal DE, Wang J, Chen J, et al. Uterine fibroids: correlations between MRI appearance and stiffness via magnetic resonance elastography. Abdom Radiol (NY). 2018. PMID: 28952003. doi:10.1007/s00261-017-1314-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。