文献速递心血管CTMR

图像减影的晚期碘增强CT评估心肌梗死

Late iodine enhancement computed tomography with image subtraction for assessment of myocardial infarction.
PubMed 文献 · Eur Radiol · 2017-09-19

研究纳入27例患者,在负荷CT灌注和CT血管成像后行晚期碘增强CT(LIE-CT),利用CT灌注数据集从左心室腔掩膜体积中减去原始LIE-CT生成减影LIE-CT。减影LIE-CT的%MI体积与LGE-MRI相关系数为0.85,透壁程度5级分级一致率为84%,均优于原始LIE-CT。

要点

  • 减影LIE-CT的%MI体积与LGE-MRI相关系数为0.85,原始LIE-CT为0.79。
  • 减影LIE-CT透壁程度5级分级一致率84%,原始LIE-CT为75%,减影技术显著提高(p<0.05)。
  • 432个节段中125个(29%)在LGE-MRI上呈阳性。

核心结论

  • 减影LIE-CT较原始LIE-CT能更准确地评估心肌梗死范围。

研究设计与样本

  • 采用综合心脏CT方案和晚期钆增强MRI(LGE-MRI)评估27例患者的冠状动脉疾病,在负荷CT灌注和CT血管成像后行LIE-CT,利用CT灌注数据集从左心室腔掩膜体积中减去原始LIE-CT生成减影LIE-CT。

诊断标准与关键数值

  • %MI体积量化为LIE与整个左心室体积的比值。
  • LIE透壁程度分为0%、1-24%、25-49%、50-74%或75-100%五级。
  • 原始与减影LIE-CT对%MI体积与LGE-MRI的相关系数分别为0.79和0.85。
  • 原始与减影LIE-CT的透壁程度5级分级与LGE-MRI一致率分别为75%和84%,减影技术一致率显著提高(p<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of image subtraction in late iodine enhancement CT (LIE-CT) for assessment of myocardial infarction (MI).

METHODS: A comprehensive cardiac CT protocol and late gadolinium enhancement MRI (LGE-MRI) was used to assess coronary artery disease in 27 patients. LIE-CT was performed after stress CT perfusion (CTP) and CT angiography. Subtraction LIE-CT was created by subtracting the mask volume of the left ventricle (LV) cavity from the original LIE-CT using CTP dataset. The %MI volume was quantified as the ratio of LIE to entire LV volume, and transmural extent (TME) of LIE was classified as 0%, 1-24%, 25-49%, 50-74% or 75-100%. These results were compared with LGE-MRI using the Spearman rank test, Bland-Altman method and chi-square test.

RESULTS: One hundred twenty-five (29%) of 432 segments were positive on LGE-MRI. Correlation coefficients for original and subtraction LIE-CT to LGE-MRI were 0.79 and 0.85 for %MI volume. Concordances of the 5-point grading scale between original and subtraction LIE-CT with LGE-MRI were 75% and 84% for TME; concordance was significantly improved using the subtraction technique (p <0.05).

CONCLUSION: Subtraction LIE-CT allowed more accurate assessment of MI extent than the original LIE-CT.

KEY POINTS: • Subtraction LIE-CT allows for accurate assessment of the extent of myocardial infarction. • Subtraction LIE-CT shows a close correlation with LGE-MRI in %MI volume. • Subtraction LIE-CT has significantly higher concordance with TME assessment than original LIE-CT.