图像减影的晚期碘增强CT评估心肌梗死
研究纳入27例患者,在负荷CT灌注和CT血管成像后行晚期碘增强CT(LIE-CT),利用CT灌注数据集从左心室腔掩膜体积中减去原始LIE-CT生成减影LIE-CT。减影LIE-CT的%MI体积与LGE-MRI相关系数为0.85,透壁程度5级分级一致率为84%,均优于原始LIE-CT。
要点
- 减影LIE-CT的%MI体积与LGE-MRI相关系数为0.85,原始LIE-CT为0.79。
- 减影LIE-CT透壁程度5级分级一致率84%,原始LIE-CT为75%,减影技术显著提高(p<0.05)。
- 432个节段中125个(29%)在LGE-MRI上呈阳性。
核心结论
- 减影LIE-CT较原始LIE-CT能更准确地评估心肌梗死范围。
研究设计与样本
- 采用综合心脏CT方案和晚期钆增强MRI(LGE-MRI)评估27例患者的冠状动脉疾病,在负荷CT灌注和CT血管成像后行LIE-CT,利用CT灌注数据集从左心室腔掩膜体积中减去原始LIE-CT生成减影LIE-CT。
诊断标准与关键数值
- %MI体积量化为LIE与整个左心室体积的比值。
- LIE透壁程度分为0%、1-24%、25-49%、50-74%或75-100%五级。
- 原始与减影LIE-CT对%MI体积与LGE-MRI的相关系数分别为0.79和0.85。
- 原始与减影LIE-CT的透壁程度5级分级与LGE-MRI一致率分别为75%和84%,减影技术一致率显著提高(p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the feasibility of image subtraction in late iodine enhancement CT (LIE-CT) for assessment of myocardial infarction (MI).
METHODS: A comprehensive cardiac CT protocol and late gadolinium enhancement MRI (LGE-MRI) was used to assess coronary artery disease in 27 patients. LIE-CT was performed after stress CT perfusion (CTP) and CT angiography. Subtraction LIE-CT was created by subtracting the mask volume of the left ventricle (LV) cavity from the original LIE-CT using CTP dataset. The %MI volume was quantified as the ratio of LIE to entire LV volume, and transmural extent (TME) of LIE was classified as 0%, 1-24%, 25-49%, 50-74% or 75-100%. These results were compared with LGE-MRI using the Spearman rank test, Bland-Altman method and chi-square test.
RESULTS: One hundred twenty-five (29%) of 432 segments were positive on LGE-MRI. Correlation coefficients for original and subtraction LIE-CT to LGE-MRI were 0.79 and 0.85 for %MI volume. Concordances of the 5-point grading scale between original and subtraction LIE-CT with LGE-MRI were 75% and 84% for TME; concordance was significantly improved using the subtraction technique (p <0.05).
CONCLUSION: Subtraction LIE-CT allowed more accurate assessment of MI extent than the original LIE-CT.
KEY POINTS: • Subtraction LIE-CT allows for accurate assessment of the extent of myocardial infarction. • Subtraction LIE-CT shows a close correlation with LGE-MRI in %MI volume. • Subtraction LIE-CT has significantly higher concordance with TME assessment than original LIE-CT.
引用
- Tanabe Y, Kido T, Kurata A, et al. Late iodine enhancement computed tomography with image subtraction for assessment of myocardial infarction. Eur Radiol. 2017. PMID: 28929333. doi:10.1007/s00330-017-5048-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。